TY - JOUR
T1 - Silver nanoparticle characterization using single particle ICP-MS (SP-ICP-MS) and asymmetrical flow field flow fractionation ICP-MS (AF4-ICP-MS)
AU - Mitrano, Denise M.
AU - Barber, Angela
AU - Bednar, Anthony
AU - Westerhoff, Paul
AU - Higgins, Christopher P.
AU - Ranville, James F.
PY - 2012/7
Y1 - 2012/7
N2 - Methods to detect, quantify, and characterize engineered nanoparticles (ENPs) in environmental matrices are highlighted as one of the areas of highest priority research needs with respect to understanding the potential environmental risks associated with nanomaterials. More specifically, techniques are needed to determine the size and concentration of ENPs in a variety of complex matrices. Furthermore, data should be collected at environmentally and toxicologically relevant concentrations. Both single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) and asymmetrical flow field flow fractionation (AF4) ICP-MS offer substantial advantages for detecting ENPs and assessing many of the above parameters in complex matrices over traditional characterization methods such as microscopy, light scattering, and filtration. In this study, we compared the ability of two emerging techniques to detect well characterized, monodisperse silver ENPs and examined their overall applicability to environmental studies specifically with respect to their: (A) size and concentration detection limits, (B) resolution and (C) multi-form elemental analysis. We find that in terms of concentration detection limit (both, on a mass basis and particle number basis) SP-ICP-MS was considerably more sensitive than AF4-ICP-MS (ng L -1vs. μg L -1, respectively), and offers the unique ability to differentiate dissolved and nanoparticulate fractions of total metal. With a variety of optimization parameters possible, AF4-ICP-MS can detect a much smaller NP size (2 nm vs. 20 nm for SP-ICP-MS), provides the possibility for greater size resolution.
AB - Methods to detect, quantify, and characterize engineered nanoparticles (ENPs) in environmental matrices are highlighted as one of the areas of highest priority research needs with respect to understanding the potential environmental risks associated with nanomaterials. More specifically, techniques are needed to determine the size and concentration of ENPs in a variety of complex matrices. Furthermore, data should be collected at environmentally and toxicologically relevant concentrations. Both single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) and asymmetrical flow field flow fractionation (AF4) ICP-MS offer substantial advantages for detecting ENPs and assessing many of the above parameters in complex matrices over traditional characterization methods such as microscopy, light scattering, and filtration. In this study, we compared the ability of two emerging techniques to detect well characterized, monodisperse silver ENPs and examined their overall applicability to environmental studies specifically with respect to their: (A) size and concentration detection limits, (B) resolution and (C) multi-form elemental analysis. We find that in terms of concentration detection limit (both, on a mass basis and particle number basis) SP-ICP-MS was considerably more sensitive than AF4-ICP-MS (ng L -1vs. μg L -1, respectively), and offers the unique ability to differentiate dissolved and nanoparticulate fractions of total metal. With a variety of optimization parameters possible, AF4-ICP-MS can detect a much smaller NP size (2 nm vs. 20 nm for SP-ICP-MS), provides the possibility for greater size resolution.
UR - http://www.scopus.com/inward/record.url?scp=84862570231&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84862570231&partnerID=8YFLogxK
U2 - 10.1039/c2ja30021d
DO - 10.1039/c2ja30021d
M3 - Article
AN - SCOPUS:84862570231
SN - 0267-9477
VL - 27
SP - 1131
EP - 1142
JO - Journal of Analytical Atomic Spectrometry
JF - Journal of Analytical Atomic Spectrometry
IS - 7
ER -