METHOD TO ANALYZE VOLTAGE RESONANCE IN POWER SYSTEMS.

L. A. Kraft, G. T. Heydt

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

While the appearance of nonlinear devices as loads in electric power systems is not a new phenomenon, this sector of the total demand is significantly increasing and has reached substantial levels in many areas. Experience has shown that the configuration of the power system to which these devices are attached can be such as to cause a resonance condition to develop. This paper proposes a method to evaluate a system configuration so that an evaluation of possible problems due to harmonic voltage resonance can be made. This paper also offers a method of determining the harmonic voltage magnitudes which can develop at any bus in the system due to the voltage resonance. This method will produce results with enough accuracy to reduce the need to run multiple Newton-Raphson power flow studies which have been modified to permit the inclusion of harmonic voltages and currents.

Original languageEnglish (US)
Title of host publicationUnknown Host Publication Title
Place of PublicationNew York, NY, USA
PublisherIEEE
StatePublished - 1983
Externally publishedYes

Fingerprint

Electric potential
Electric power systems

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Kraft, L. A., & Heydt, G. T. (1983). METHOD TO ANALYZE VOLTAGE RESONANCE IN POWER SYSTEMS. In Unknown Host Publication Title New York, NY, USA: IEEE.

METHOD TO ANALYZE VOLTAGE RESONANCE IN POWER SYSTEMS. / Kraft, L. A.; Heydt, G. T.

Unknown Host Publication Title. New York, NY, USA : IEEE, 1983.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Kraft, LA & Heydt, GT 1983, METHOD TO ANALYZE VOLTAGE RESONANCE IN POWER SYSTEMS. in Unknown Host Publication Title. IEEE, New York, NY, USA.
Kraft LA, Heydt GT. METHOD TO ANALYZE VOLTAGE RESONANCE IN POWER SYSTEMS. In Unknown Host Publication Title. New York, NY, USA: IEEE. 1983
Kraft, L. A. ; Heydt, G. T. / METHOD TO ANALYZE VOLTAGE RESONANCE IN POWER SYSTEMS. Unknown Host Publication Title. New York, NY, USA : IEEE, 1983.
@inproceedings{1d295ac3117548cfb3929dff6f199e0c,
title = "METHOD TO ANALYZE VOLTAGE RESONANCE IN POWER SYSTEMS.",
abstract = "While the appearance of nonlinear devices as loads in electric power systems is not a new phenomenon, this sector of the total demand is significantly increasing and has reached substantial levels in many areas. Experience has shown that the configuration of the power system to which these devices are attached can be such as to cause a resonance condition to develop. This paper proposes a method to evaluate a system configuration so that an evaluation of possible problems due to harmonic voltage resonance can be made. This paper also offers a method of determining the harmonic voltage magnitudes which can develop at any bus in the system due to the voltage resonance. This method will produce results with enough accuracy to reduce the need to run multiple Newton-Raphson power flow studies which have been modified to permit the inclusion of harmonic voltages and currents.",
author = "Kraft, {L. A.} and Heydt, {G. T.}",
year = "1983",
language = "English (US)",
booktitle = "Unknown Host Publication Title",
publisher = "IEEE",

}

TY - GEN

T1 - METHOD TO ANALYZE VOLTAGE RESONANCE IN POWER SYSTEMS.

AU - Kraft, L. A.

AU - Heydt, G. T.

PY - 1983

Y1 - 1983

N2 - While the appearance of nonlinear devices as loads in electric power systems is not a new phenomenon, this sector of the total demand is significantly increasing and has reached substantial levels in many areas. Experience has shown that the configuration of the power system to which these devices are attached can be such as to cause a resonance condition to develop. This paper proposes a method to evaluate a system configuration so that an evaluation of possible problems due to harmonic voltage resonance can be made. This paper also offers a method of determining the harmonic voltage magnitudes which can develop at any bus in the system due to the voltage resonance. This method will produce results with enough accuracy to reduce the need to run multiple Newton-Raphson power flow studies which have been modified to permit the inclusion of harmonic voltages and currents.

AB - While the appearance of nonlinear devices as loads in electric power systems is not a new phenomenon, this sector of the total demand is significantly increasing and has reached substantial levels in many areas. Experience has shown that the configuration of the power system to which these devices are attached can be such as to cause a resonance condition to develop. This paper proposes a method to evaluate a system configuration so that an evaluation of possible problems due to harmonic voltage resonance can be made. This paper also offers a method of determining the harmonic voltage magnitudes which can develop at any bus in the system due to the voltage resonance. This method will produce results with enough accuracy to reduce the need to run multiple Newton-Raphson power flow studies which have been modified to permit the inclusion of harmonic voltages and currents.

UR - http://www.scopus.com/inward/record.url?scp=0020862407&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0020862407&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:0020862407

BT - Unknown Host Publication Title

PB - IEEE

CY - New York, NY, USA

ER -