TY - JOUR
T1 - High-power-density high-efficiency LLC converter with an adjustable-leakage-inductance planar transformer for data centers
AU - He, Peiwen
AU - Mallik, Ayan
AU - Cooke, Gary
AU - Khaligh, Alireza
N1 - Publisher Copyright:
© The Institution of Engineering and Technology 2018.
Copyright:
Copyright 2019 Elsevier B.V., All rights reserved.
PY - 2019/2/20
Y1 - 2019/2/20
N2 - LLC converters can achieve high efficiency, high-power density, wide gain range, and galvanic isolation. This study presents a high-power-density and high-efficiency LLC converter with an adjustable-leakage-inductance planar transformer for the DC–DC conversion in data center power supplies. A planar transformer with adjustable leakage inductance is modelled and developed to provide an accurate design for resonant frequency and voltage gain. A detailed power loss analysis is performed. Furthermore, a thermal model is provided to aid in heat sink design. GaN devices are used in the converter to achieve high-switching frequency and low-switching loss. A 450 kHz, 360–400 V DC input, 12 V DC output, 750 W LLC converter prototype with an adjustable-leakage-inductance planar transformer is built and tested. The power density of the system is 15.4 W/cm 3 including an auxiliary power supply. The peak efficiency of the overall system is over 95%.
AB - LLC converters can achieve high efficiency, high-power density, wide gain range, and galvanic isolation. This study presents a high-power-density and high-efficiency LLC converter with an adjustable-leakage-inductance planar transformer for the DC–DC conversion in data center power supplies. A planar transformer with adjustable leakage inductance is modelled and developed to provide an accurate design for resonant frequency and voltage gain. A detailed power loss analysis is performed. Furthermore, a thermal model is provided to aid in heat sink design. GaN devices are used in the converter to achieve high-switching frequency and low-switching loss. A 450 kHz, 360–400 V DC input, 12 V DC output, 750 W LLC converter prototype with an adjustable-leakage-inductance planar transformer is built and tested. The power density of the system is 15.4 W/cm 3 including an auxiliary power supply. The peak efficiency of the overall system is over 95%.
UR - http://www.scopus.com/inward/record.url?scp=85061330475&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85061330475&partnerID=8YFLogxK
U2 - 10.1049/iet-pel.2018.5299
DO - 10.1049/iet-pel.2018.5299
M3 - Article
AN - SCOPUS:85061330475
SN - 1755-4535
VL - 12
SP - 303
EP - 310
JO - IET Power Electronics
JF - IET Power Electronics
IS - 2
ER -