ELECTRICAL AND CONTAMINATION PERFORMANCE OF SYNTHETIC INSULATORS FOR 735-kV TRANSMISSION LINES.

G. Karady, G. Lamontagne

Research output: Contribution to conferencePaper

Abstract

The paper presents the results of electrical tests (60-Hz, switching and lightning impulses) and contamination tests performed on four different types of synthetic insulator (rated 735 kv) and on a chain of 32 standard insulators. The performance of the different synthetic insulators is analyzed and compared with that of porcelain insulators and the major parameters influencing insulator behavior are discussed. The flashover mechanism of contaminated synthetic insulators is investigated and the results show that while the electrical performance of these insulators is more or less the same as that of porcelain ones, their contamination performance, when new, is far superior.

Original languageEnglish (US)
StatePublished - Jan 1 2017
EventIEEE Power Eng Soc Text of 'A' Pap from the Summer Meet - Portland, OR, USA
Duration: Jul 18 1976Jul 23 1976

Other

OtherIEEE Power Eng Soc Text of 'A' Pap from the Summer Meet
CityPortland, OR, USA
Period7/18/767/23/76

Fingerprint

Porcelain
Contamination
Flashover
Lightning

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Karady, G., & Lamontagne, G. (2017). ELECTRICAL AND CONTAMINATION PERFORMANCE OF SYNTHETIC INSULATORS FOR 735-kV TRANSMISSION LINES.. Paper presented at IEEE Power Eng Soc Text of 'A' Pap from the Summer Meet, Portland, OR, USA, .

ELECTRICAL AND CONTAMINATION PERFORMANCE OF SYNTHETIC INSULATORS FOR 735-kV TRANSMISSION LINES. / Karady, G.; Lamontagne, G.

2017. Paper presented at IEEE Power Eng Soc Text of 'A' Pap from the Summer Meet, Portland, OR, USA, .

Research output: Contribution to conferencePaper

Karady, G & Lamontagne, G 2017, 'ELECTRICAL AND CONTAMINATION PERFORMANCE OF SYNTHETIC INSULATORS FOR 735-kV TRANSMISSION LINES.' Paper presented at IEEE Power Eng Soc Text of 'A' Pap from the Summer Meet, Portland, OR, USA, 7/18/76 - 7/23/76, .
Karady G, Lamontagne G. ELECTRICAL AND CONTAMINATION PERFORMANCE OF SYNTHETIC INSULATORS FOR 735-kV TRANSMISSION LINES.. 2017. Paper presented at IEEE Power Eng Soc Text of 'A' Pap from the Summer Meet, Portland, OR, USA, .
Karady, G. ; Lamontagne, G. / ELECTRICAL AND CONTAMINATION PERFORMANCE OF SYNTHETIC INSULATORS FOR 735-kV TRANSMISSION LINES. Paper presented at IEEE Power Eng Soc Text of 'A' Pap from the Summer Meet, Portland, OR, USA, .
@conference{8185700990fb439598b612d1c7ad2e16,
title = "ELECTRICAL AND CONTAMINATION PERFORMANCE OF SYNTHETIC INSULATORS FOR 735-kV TRANSMISSION LINES.",
abstract = "The paper presents the results of electrical tests (60-Hz, switching and lightning impulses) and contamination tests performed on four different types of synthetic insulator (rated 735 kv) and on a chain of 32 standard insulators. The performance of the different synthetic insulators is analyzed and compared with that of porcelain insulators and the major parameters influencing insulator behavior are discussed. The flashover mechanism of contaminated synthetic insulators is investigated and the results show that while the electrical performance of these insulators is more or less the same as that of porcelain ones, their contamination performance, when new, is far superior.",
author = "G. Karady and G. Lamontagne",
year = "2017",
month = "1",
day = "1",
language = "English (US)",
note = "IEEE Power Eng Soc Text of 'A' Pap from the Summer Meet ; Conference date: 18-07-1976 Through 23-07-1976",

}

TY - CONF

T1 - ELECTRICAL AND CONTAMINATION PERFORMANCE OF SYNTHETIC INSULATORS FOR 735-kV TRANSMISSION LINES.

AU - Karady, G.

AU - Lamontagne, G.

PY - 2017/1/1

Y1 - 2017/1/1

N2 - The paper presents the results of electrical tests (60-Hz, switching and lightning impulses) and contamination tests performed on four different types of synthetic insulator (rated 735 kv) and on a chain of 32 standard insulators. The performance of the different synthetic insulators is analyzed and compared with that of porcelain insulators and the major parameters influencing insulator behavior are discussed. The flashover mechanism of contaminated synthetic insulators is investigated and the results show that while the electrical performance of these insulators is more or less the same as that of porcelain ones, their contamination performance, when new, is far superior.

AB - The paper presents the results of electrical tests (60-Hz, switching and lightning impulses) and contamination tests performed on four different types of synthetic insulator (rated 735 kv) and on a chain of 32 standard insulators. The performance of the different synthetic insulators is analyzed and compared with that of porcelain insulators and the major parameters influencing insulator behavior are discussed. The flashover mechanism of contaminated synthetic insulators is investigated and the results show that while the electrical performance of these insulators is more or less the same as that of porcelain ones, their contamination performance, when new, is far superior.

UR - http://www.scopus.com/inward/record.url?scp=85041983108&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85041983108&partnerID=8YFLogxK

M3 - Paper

ER -