Direct analysis of biological samples using extractive electrospray ionization mass spectrometry (EESI-MS)

Haiwei Gu, Ning Xu, Huanwen Chen

Research output: Contribution to journalReview article

28 Citations (Scopus)

Abstract

Abstract Mass spectrometry (MS) is one of the most widely used techniques for the analysis of biological samples. In the past decade, a novel improvement in MS was the invention of ambient ionization which stands out owing to its unique capability of direct analysis of complex samples with no or minimal pretreatment. In this review, extractive electrospray ionization (EESI), a representative ambient ionization technique, is introduced focusing on its mechanism, instrumentation, and applications in biological analysis. EESI uses a traditional ESI channel to produce primary ions which subsequently ionize neutral chemicals from the sample introduction channel through an online extraction process. When analyzing biological samples, EESI has advantages of rapid analysis, high matrix tolerance, and the ability to perform in vivo analysis. According to previous studies, EESI is able to directly analyze various chemicals in complex biological specimens in liquid, gas, and solid states. EESI can provide a sensitive and selective measurement of biological samples for both qualitative and quantitative purposes. Therefore, it is anticipated that EESI will have promising applications, especially in fields which require the fast and/or in vivo analysis of biological samples with complicated matrixes.

Original languageEnglish (US)
Pages (from-to)2145-2153
Number of pages9
JournalAnalytical and Bioanalytical Chemistry
Volume403
Issue number8
DOIs
StatePublished - Jun 1 2012
Externally publishedYes

Fingerprint

Electrospray ionization
Electrospray Ionization Mass Spectrometry
Mass spectrometry
Mass Spectrometry
Gases
Ions
Ionization
Patents and inventions
Liquids

Keywords

  • Ambient mass spectrometry
  • Biological samples
  • Direct analysis
  • Extractive electrospray ionization (EESI)

ASJC Scopus subject areas

  • Analytical Chemistry
  • Biochemistry

Cite this

Direct analysis of biological samples using extractive electrospray ionization mass spectrometry (EESI-MS). / Gu, Haiwei; Xu, Ning; Chen, Huanwen.

In: Analytical and Bioanalytical Chemistry, Vol. 403, No. 8, 01.06.2012, p. 2145-2153.

Research output: Contribution to journalReview article

@article{13abe3c8fad8453bb2e2e6e5ebeb6f26,
title = "Direct analysis of biological samples using extractive electrospray ionization mass spectrometry (EESI-MS)",
abstract = "Abstract Mass spectrometry (MS) is one of the most widely used techniques for the analysis of biological samples. In the past decade, a novel improvement in MS was the invention of ambient ionization which stands out owing to its unique capability of direct analysis of complex samples with no or minimal pretreatment. In this review, extractive electrospray ionization (EESI), a representative ambient ionization technique, is introduced focusing on its mechanism, instrumentation, and applications in biological analysis. EESI uses a traditional ESI channel to produce primary ions which subsequently ionize neutral chemicals from the sample introduction channel through an online extraction process. When analyzing biological samples, EESI has advantages of rapid analysis, high matrix tolerance, and the ability to perform in vivo analysis. According to previous studies, EESI is able to directly analyze various chemicals in complex biological specimens in liquid, gas, and solid states. EESI can provide a sensitive and selective measurement of biological samples for both qualitative and quantitative purposes. Therefore, it is anticipated that EESI will have promising applications, especially in fields which require the fast and/or in vivo analysis of biological samples with complicated matrixes.",
keywords = "Ambient mass spectrometry, Biological samples, Direct analysis, Extractive electrospray ionization (EESI)",
author = "Haiwei Gu and Ning Xu and Huanwen Chen",
year = "2012",
month = "6",
day = "1",
doi = "10.1007/s00216-012-5874-1",
language = "English (US)",
volume = "403",
pages = "2145--2153",
journal = "Fresenius Zeitschrift fur Analytische Chemie",
issn = "0016-1152",
publisher = "Springer Verlag",
number = "8",

}

TY - JOUR

T1 - Direct analysis of biological samples using extractive electrospray ionization mass spectrometry (EESI-MS)

AU - Gu, Haiwei

AU - Xu, Ning

AU - Chen, Huanwen

PY - 2012/6/1

Y1 - 2012/6/1

N2 - Abstract Mass spectrometry (MS) is one of the most widely used techniques for the analysis of biological samples. In the past decade, a novel improvement in MS was the invention of ambient ionization which stands out owing to its unique capability of direct analysis of complex samples with no or minimal pretreatment. In this review, extractive electrospray ionization (EESI), a representative ambient ionization technique, is introduced focusing on its mechanism, instrumentation, and applications in biological analysis. EESI uses a traditional ESI channel to produce primary ions which subsequently ionize neutral chemicals from the sample introduction channel through an online extraction process. When analyzing biological samples, EESI has advantages of rapid analysis, high matrix tolerance, and the ability to perform in vivo analysis. According to previous studies, EESI is able to directly analyze various chemicals in complex biological specimens in liquid, gas, and solid states. EESI can provide a sensitive and selective measurement of biological samples for both qualitative and quantitative purposes. Therefore, it is anticipated that EESI will have promising applications, especially in fields which require the fast and/or in vivo analysis of biological samples with complicated matrixes.

AB - Abstract Mass spectrometry (MS) is one of the most widely used techniques for the analysis of biological samples. In the past decade, a novel improvement in MS was the invention of ambient ionization which stands out owing to its unique capability of direct analysis of complex samples with no or minimal pretreatment. In this review, extractive electrospray ionization (EESI), a representative ambient ionization technique, is introduced focusing on its mechanism, instrumentation, and applications in biological analysis. EESI uses a traditional ESI channel to produce primary ions which subsequently ionize neutral chemicals from the sample introduction channel through an online extraction process. When analyzing biological samples, EESI has advantages of rapid analysis, high matrix tolerance, and the ability to perform in vivo analysis. According to previous studies, EESI is able to directly analyze various chemicals in complex biological specimens in liquid, gas, and solid states. EESI can provide a sensitive and selective measurement of biological samples for both qualitative and quantitative purposes. Therefore, it is anticipated that EESI will have promising applications, especially in fields which require the fast and/or in vivo analysis of biological samples with complicated matrixes.

KW - Ambient mass spectrometry

KW - Biological samples

KW - Direct analysis

KW - Extractive electrospray ionization (EESI)

UR - http://www.scopus.com/inward/record.url?scp=84863727473&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84863727473&partnerID=8YFLogxK

U2 - 10.1007/s00216-012-5874-1

DO - 10.1007/s00216-012-5874-1

M3 - Review article

C2 - 22434271

AN - SCOPUS:84863727473

VL - 403

SP - 2145

EP - 2153

JO - Fresenius Zeitschrift fur Analytische Chemie

JF - Fresenius Zeitschrift fur Analytische Chemie

SN - 0016-1152

IS - 8

ER -