A precise electron beam energy calibration for use in nuclear physics

T. Zwart, Ricardo Alarcon, E. Booth, G. Dodson, S. Dolfini, K. Dow, M. Farkhondeh, K. Jacobs, K. Joo, S. Kowalski, S. Soong, J. Shaw, W. Turchinetz, E. Tsentalovich, B. Wojtsekhowski, A. Young

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

An accurate calibration of the MIT-Bates electron beam energy has been achieved. The electron beam was injected into the MIT-Bates South Hall Ring and the spin-precession frequency, Ωs, was measured. From the spin-precession frequency the equilibrium energy of the ring was determined to be 370.3115±0.0021±0.0004 MeV, where the first error is statistical and the second is systematic. The energy of the beam delivered by the linac was determined to be 369.954±0.023±0.300 MeV. This provides a rigorous check on the accuracy of the facility's energy analyzing magnets. The first moment of the energy distribution was also measured. By observing the time constant of the spin diffusion with zero power in the South Hall Ring RF cavity, we obtained a value of σγ/γ = (3.7±0.5) × 10-4. We provide a lower limit to the polarization lifetime. At a beam energy of 370 MeV no measurable decrease in the polarization was observed up to 2 ms after injection.

Original languageEnglish (US)
Pages (from-to)299-306
Number of pages8
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume384
Issue number2-3
DOIs
StatePublished - Jan 1 1997

Fingerprint

Nuclear physics
nuclear physics
Electron beams
Calibration
electron beams
Polarization
Magnets
precession
rings
energy
polarization
time constant
energy distribution
magnets
injection
moments
life (durability)
cavities

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics

Cite this

A precise electron beam energy calibration for use in nuclear physics. / Zwart, T.; Alarcon, Ricardo; Booth, E.; Dodson, G.; Dolfini, S.; Dow, K.; Farkhondeh, M.; Jacobs, K.; Joo, K.; Kowalski, S.; Soong, S.; Shaw, J.; Turchinetz, W.; Tsentalovich, E.; Wojtsekhowski, B.; Young, A.

In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 384, No. 2-3, 01.01.1997, p. 299-306.

Research output: Contribution to journalArticle

Zwart, T, Alarcon, R, Booth, E, Dodson, G, Dolfini, S, Dow, K, Farkhondeh, M, Jacobs, K, Joo, K, Kowalski, S, Soong, S, Shaw, J, Turchinetz, W, Tsentalovich, E, Wojtsekhowski, B & Young, A 1997, 'A precise electron beam energy calibration for use in nuclear physics', Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 384, no. 2-3, pp. 299-306. https://doi.org/10.1016/S0168-9002(96)00723-1
Zwart, T. ; Alarcon, Ricardo ; Booth, E. ; Dodson, G. ; Dolfini, S. ; Dow, K. ; Farkhondeh, M. ; Jacobs, K. ; Joo, K. ; Kowalski, S. ; Soong, S. ; Shaw, J. ; Turchinetz, W. ; Tsentalovich, E. ; Wojtsekhowski, B. ; Young, A. / A precise electron beam energy calibration for use in nuclear physics. In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 1997 ; Vol. 384, No. 2-3. pp. 299-306.
@article{83919a90153a4b1fb4d7cd8a51b3d279,
title = "A precise electron beam energy calibration for use in nuclear physics",
abstract = "An accurate calibration of the MIT-Bates electron beam energy has been achieved. The electron beam was injected into the MIT-Bates South Hall Ring and the spin-precession frequency, Ωs, was measured. From the spin-precession frequency the equilibrium energy of the ring was determined to be 370.3115±0.0021±0.0004 MeV, where the first error is statistical and the second is systematic. The energy of the beam delivered by the linac was determined to be 369.954±0.023±0.300 MeV. This provides a rigorous check on the accuracy of the facility's energy analyzing magnets. The first moment of the energy distribution was also measured. By observing the time constant of the spin diffusion with zero power in the South Hall Ring RF cavity, we obtained a value of σγ/γ = (3.7±0.5) × 10-4. We provide a lower limit to the polarization lifetime. At a beam energy of 370 MeV no measurable decrease in the polarization was observed up to 2 ms after injection.",
author = "T. Zwart and Ricardo Alarcon and E. Booth and G. Dodson and S. Dolfini and K. Dow and M. Farkhondeh and K. Jacobs and K. Joo and S. Kowalski and S. Soong and J. Shaw and W. Turchinetz and E. Tsentalovich and B. Wojtsekhowski and A. Young",
year = "1997",
month = "1",
day = "1",
doi = "10.1016/S0168-9002(96)00723-1",
language = "English (US)",
volume = "384",
pages = "299--306",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "2-3",

}

TY - JOUR

T1 - A precise electron beam energy calibration for use in nuclear physics

AU - Zwart, T.

AU - Alarcon, Ricardo

AU - Booth, E.

AU - Dodson, G.

AU - Dolfini, S.

AU - Dow, K.

AU - Farkhondeh, M.

AU - Jacobs, K.

AU - Joo, K.

AU - Kowalski, S.

AU - Soong, S.

AU - Shaw, J.

AU - Turchinetz, W.

AU - Tsentalovich, E.

AU - Wojtsekhowski, B.

AU - Young, A.

PY - 1997/1/1

Y1 - 1997/1/1

N2 - An accurate calibration of the MIT-Bates electron beam energy has been achieved. The electron beam was injected into the MIT-Bates South Hall Ring and the spin-precession frequency, Ωs, was measured. From the spin-precession frequency the equilibrium energy of the ring was determined to be 370.3115±0.0021±0.0004 MeV, where the first error is statistical and the second is systematic. The energy of the beam delivered by the linac was determined to be 369.954±0.023±0.300 MeV. This provides a rigorous check on the accuracy of the facility's energy analyzing magnets. The first moment of the energy distribution was also measured. By observing the time constant of the spin diffusion with zero power in the South Hall Ring RF cavity, we obtained a value of σγ/γ = (3.7±0.5) × 10-4. We provide a lower limit to the polarization lifetime. At a beam energy of 370 MeV no measurable decrease in the polarization was observed up to 2 ms after injection.

AB - An accurate calibration of the MIT-Bates electron beam energy has been achieved. The electron beam was injected into the MIT-Bates South Hall Ring and the spin-precession frequency, Ωs, was measured. From the spin-precession frequency the equilibrium energy of the ring was determined to be 370.3115±0.0021±0.0004 MeV, where the first error is statistical and the second is systematic. The energy of the beam delivered by the linac was determined to be 369.954±0.023±0.300 MeV. This provides a rigorous check on the accuracy of the facility's energy analyzing magnets. The first moment of the energy distribution was also measured. By observing the time constant of the spin diffusion with zero power in the South Hall Ring RF cavity, we obtained a value of σγ/γ = (3.7±0.5) × 10-4. We provide a lower limit to the polarization lifetime. At a beam energy of 370 MeV no measurable decrease in the polarization was observed up to 2 ms after injection.

UR - http://www.scopus.com/inward/record.url?scp=0030788826&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030788826&partnerID=8YFLogxK

U2 - 10.1016/S0168-9002(96)00723-1

DO - 10.1016/S0168-9002(96)00723-1

M3 - Article

AN - SCOPUS:0030788826

VL - 384

SP - 299

EP - 306

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 2-3

ER -