X-ray-optical pump-probe experiments at the Linac Coherent Light Source (LCLS) have so far been limited to a time resolution of 280 fs fwhm due to timing jitter between the accelerator-based free-electron laser (FEL) and optical lasers. We have implemented a single-shot cross-correlator for femtosecond x-ray and infrared pulses. A reference experiment relying only on the pulse arrival time information from the cross-correlator shows a time resolution better than 50 fs fwhm (22 fs rms) and also yields a direct measurement of the maximal x-ray pulse length. The improved time resolution enables ultrafast pump-probe experiments with x-ray pulses from LCLS and other FEL sources.

Original languageEnglish (US)
Article number121107
JournalApplied Physics Letters
Volume100
Issue number12
DOIs
StatePublished - Mar 19 2012
Externally publishedYes

Fingerprint

coherent light
correlators
free electron lasers
light sources
vapor phases
pulses
x rays
pumps
probes
shot
arrivals
accelerators
time measurement
vibration
lasers

ASJC Scopus subject areas

  • Physics and Astronomy (miscellaneous)

Cite this

Schorb, S., Gorkhover, T., Cryan, J. P., Glownia, J. M., Bionta, M. R., Coffee, R. N., ... Bostedt, C. (2012). X-ray-optical cross-correlator for gas-phase experiments at the Linac Coherent Light Source free-electron laser. Applied Physics Letters, 100(12), [121107]. https://doi.org/10.1063/1.3695163

X-ray-optical cross-correlator for gas-phase experiments at the Linac Coherent Light Source free-electron laser. / Schorb, S.; Gorkhover, T.; Cryan, J. P.; Glownia, J. M.; Bionta, M. R.; Coffee, R. N.; Erk, B.; Boll, R.; Schmidt, C.; Rolles, D.; Rudenko, A.; Rouzee, A.; Swiggers, M.; Carron, S.; Castagna, J. C.; Bozek, J. D.; Messerschmidt, Marc; Schlotter, W. F.; Bostedt, C.

In: Applied Physics Letters, Vol. 100, No. 12, 121107, 19.03.2012.

Research output: Contribution to journalArticle

Schorb, S, Gorkhover, T, Cryan, JP, Glownia, JM, Bionta, MR, Coffee, RN, Erk, B, Boll, R, Schmidt, C, Rolles, D, Rudenko, A, Rouzee, A, Swiggers, M, Carron, S, Castagna, JC, Bozek, JD, Messerschmidt, M, Schlotter, WF & Bostedt, C 2012, 'X-ray-optical cross-correlator for gas-phase experiments at the Linac Coherent Light Source free-electron laser', Applied Physics Letters, vol. 100, no. 12, 121107. https://doi.org/10.1063/1.3695163
Schorb, S. ; Gorkhover, T. ; Cryan, J. P. ; Glownia, J. M. ; Bionta, M. R. ; Coffee, R. N. ; Erk, B. ; Boll, R. ; Schmidt, C. ; Rolles, D. ; Rudenko, A. ; Rouzee, A. ; Swiggers, M. ; Carron, S. ; Castagna, J. C. ; Bozek, J. D. ; Messerschmidt, Marc ; Schlotter, W. F. ; Bostedt, C. / X-ray-optical cross-correlator for gas-phase experiments at the Linac Coherent Light Source free-electron laser. In: Applied Physics Letters. 2012 ; Vol. 100, No. 12.
@article{03ae20ae20e2445faa434e1adfced9fa,
title = "X-ray-optical cross-correlator for gas-phase experiments at the Linac Coherent Light Source free-electron laser",
abstract = "X-ray-optical pump-probe experiments at the Linac Coherent Light Source (LCLS) have so far been limited to a time resolution of 280 fs fwhm due to timing jitter between the accelerator-based free-electron laser (FEL) and optical lasers. We have implemented a single-shot cross-correlator for femtosecond x-ray and infrared pulses. A reference experiment relying only on the pulse arrival time information from the cross-correlator shows a time resolution better than 50 fs fwhm (22 fs rms) and also yields a direct measurement of the maximal x-ray pulse length. The improved time resolution enables ultrafast pump-probe experiments with x-ray pulses from LCLS and other FEL sources.",
author = "S. Schorb and T. Gorkhover and Cryan, {J. P.} and Glownia, {J. M.} and Bionta, {M. R.} and Coffee, {R. N.} and B. Erk and R. Boll and C. Schmidt and D. Rolles and A. Rudenko and A. Rouzee and M. Swiggers and S. Carron and Castagna, {J. C.} and Bozek, {J. D.} and Marc Messerschmidt and Schlotter, {W. F.} and C. Bostedt",
year = "2012",
month = "3",
day = "19",
doi = "10.1063/1.3695163",
language = "English (US)",
volume = "100",
journal = "Applied Physics Letters",
issn = "0003-6951",
publisher = "American Institute of Physics Publising LLC",
number = "12",

}

TY - JOUR

T1 - X-ray-optical cross-correlator for gas-phase experiments at the Linac Coherent Light Source free-electron laser

AU - Schorb, S.

AU - Gorkhover, T.

AU - Cryan, J. P.

AU - Glownia, J. M.

AU - Bionta, M. R.

AU - Coffee, R. N.

AU - Erk, B.

AU - Boll, R.

AU - Schmidt, C.

AU - Rolles, D.

AU - Rudenko, A.

AU - Rouzee, A.

AU - Swiggers, M.

AU - Carron, S.

AU - Castagna, J. C.

AU - Bozek, J. D.

AU - Messerschmidt, Marc

AU - Schlotter, W. F.

AU - Bostedt, C.

PY - 2012/3/19

Y1 - 2012/3/19

N2 - X-ray-optical pump-probe experiments at the Linac Coherent Light Source (LCLS) have so far been limited to a time resolution of 280 fs fwhm due to timing jitter between the accelerator-based free-electron laser (FEL) and optical lasers. We have implemented a single-shot cross-correlator for femtosecond x-ray and infrared pulses. A reference experiment relying only on the pulse arrival time information from the cross-correlator shows a time resolution better than 50 fs fwhm (22 fs rms) and also yields a direct measurement of the maximal x-ray pulse length. The improved time resolution enables ultrafast pump-probe experiments with x-ray pulses from LCLS and other FEL sources.

AB - X-ray-optical pump-probe experiments at the Linac Coherent Light Source (LCLS) have so far been limited to a time resolution of 280 fs fwhm due to timing jitter between the accelerator-based free-electron laser (FEL) and optical lasers. We have implemented a single-shot cross-correlator for femtosecond x-ray and infrared pulses. A reference experiment relying only on the pulse arrival time information from the cross-correlator shows a time resolution better than 50 fs fwhm (22 fs rms) and also yields a direct measurement of the maximal x-ray pulse length. The improved time resolution enables ultrafast pump-probe experiments with x-ray pulses from LCLS and other FEL sources.

UR - http://www.scopus.com/inward/record.url?scp=84859524701&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84859524701&partnerID=8YFLogxK

U2 - 10.1063/1.3695163

DO - 10.1063/1.3695163

M3 - Article

AN - SCOPUS:84859524701

VL - 100

JO - Applied Physics Letters

JF - Applied Physics Letters

SN - 0003-6951

IS - 12

M1 - 121107

ER -