Wafer-level vacuum package with vertical feedthroughs

Junseok Chae, Joseph M. Giachino, Khalil Najafi

Research output: Chapter in Book/Report/Conference proceedingConference contribution

21 Citations (Scopus)

Abstract

This paper reports a MEMS vacuum package with vertical feedthroughs formed in a glass substrate all at the wafer level. This approach satisfies requirements for MEMS vacuum packages, including small size, vacuum/hermetic capability, sealed and low parasitic feedthroughs, wafer level processing, compatibility with most MEMS processes, and low cost. It also enables flip-chip solder attachment to a PC board. The package has an integrated micro-Pirani gauge on a glass substrate for in-situ monitoring, silicon cap, and vertical feedthroughs through the glass. The integrated Pirani gauge has 0.1Torr resolution at 0.1Torr and 0.2Torr resolution at 100Torr. Using the Pirani gauge, we have achieved ∼11Torr base pressure inside the vacuum package without a getter. Another package sealed at ∼80Torr has maintained its pressure for more than 2 months.

Original languageEnglish (US)
Title of host publicationProceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)
Pages548-551
Number of pages4
StatePublished - 2005
Externally publishedYes
Event18th IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2005 Miami - Miami Beach, FL, United States
Duration: Jan 30 2005Feb 3 2005

Other

Other18th IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2005 Miami
CountryUnited States
CityMiami Beach, FL
Period1/30/052/3/05

Fingerprint

Vacuum
Gages
MEMS
Glass
Substrates
Soldering alloys
Silicon
Monitoring
Processing
Costs

Keywords

  • Packaging
  • Pirani gauge
  • Vacuum package
  • Vertical feedthroughs

ASJC Scopus subject areas

  • Mechanical Engineering
  • Electrical and Electronic Engineering
  • Control and Systems Engineering

Cite this

Chae, J., Giachino, J. M., & Najafi, K. (2005). Wafer-level vacuum package with vertical feedthroughs. In Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS) (pp. 548-551). [TPb31]

Wafer-level vacuum package with vertical feedthroughs. / Chae, Junseok; Giachino, Joseph M.; Najafi, Khalil.

Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS). 2005. p. 548-551 TPb31.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Chae, J, Giachino, JM & Najafi, K 2005, Wafer-level vacuum package with vertical feedthroughs. in Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)., TPb31, pp. 548-551, 18th IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2005 Miami, Miami Beach, FL, United States, 1/30/05.
Chae J, Giachino JM, Najafi K. Wafer-level vacuum package with vertical feedthroughs. In Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS). 2005. p. 548-551. TPb31
Chae, Junseok ; Giachino, Joseph M. ; Najafi, Khalil. / Wafer-level vacuum package with vertical feedthroughs. Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS). 2005. pp. 548-551
@inproceedings{39d13fd4d983467e994c0412f3e4036c,
title = "Wafer-level vacuum package with vertical feedthroughs",
abstract = "This paper reports a MEMS vacuum package with vertical feedthroughs formed in a glass substrate all at the wafer level. This approach satisfies requirements for MEMS vacuum packages, including small size, vacuum/hermetic capability, sealed and low parasitic feedthroughs, wafer level processing, compatibility with most MEMS processes, and low cost. It also enables flip-chip solder attachment to a PC board. The package has an integrated micro-Pirani gauge on a glass substrate for in-situ monitoring, silicon cap, and vertical feedthroughs through the glass. The integrated Pirani gauge has 0.1Torr resolution at 0.1Torr and 0.2Torr resolution at 100Torr. Using the Pirani gauge, we have achieved ∼11Torr base pressure inside the vacuum package without a getter. Another package sealed at ∼80Torr has maintained its pressure for more than 2 months.",
keywords = "Packaging, Pirani gauge, Vacuum package, Vertical feedthroughs",
author = "Junseok Chae and Giachino, {Joseph M.} and Khalil Najafi",
year = "2005",
language = "English (US)",
pages = "548--551",
booktitle = "Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)",

}

TY - GEN

T1 - Wafer-level vacuum package with vertical feedthroughs

AU - Chae, Junseok

AU - Giachino, Joseph M.

AU - Najafi, Khalil

PY - 2005

Y1 - 2005

N2 - This paper reports a MEMS vacuum package with vertical feedthroughs formed in a glass substrate all at the wafer level. This approach satisfies requirements for MEMS vacuum packages, including small size, vacuum/hermetic capability, sealed and low parasitic feedthroughs, wafer level processing, compatibility with most MEMS processes, and low cost. It also enables flip-chip solder attachment to a PC board. The package has an integrated micro-Pirani gauge on a glass substrate for in-situ monitoring, silicon cap, and vertical feedthroughs through the glass. The integrated Pirani gauge has 0.1Torr resolution at 0.1Torr and 0.2Torr resolution at 100Torr. Using the Pirani gauge, we have achieved ∼11Torr base pressure inside the vacuum package without a getter. Another package sealed at ∼80Torr has maintained its pressure for more than 2 months.

AB - This paper reports a MEMS vacuum package with vertical feedthroughs formed in a glass substrate all at the wafer level. This approach satisfies requirements for MEMS vacuum packages, including small size, vacuum/hermetic capability, sealed and low parasitic feedthroughs, wafer level processing, compatibility with most MEMS processes, and low cost. It also enables flip-chip solder attachment to a PC board. The package has an integrated micro-Pirani gauge on a glass substrate for in-situ monitoring, silicon cap, and vertical feedthroughs through the glass. The integrated Pirani gauge has 0.1Torr resolution at 0.1Torr and 0.2Torr resolution at 100Torr. Using the Pirani gauge, we have achieved ∼11Torr base pressure inside the vacuum package without a getter. Another package sealed at ∼80Torr has maintained its pressure for more than 2 months.

KW - Packaging

KW - Pirani gauge

KW - Vacuum package

KW - Vertical feedthroughs

UR - http://www.scopus.com/inward/record.url?scp=26844529375&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=26844529375&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:26844529375

SP - 548

EP - 551

BT - Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS)

ER -