Validity of the Instrumented Push and Release Test to Quantify Postural Responses in Persons With Multiple Sclerosis

Mahmoud El-Gohary, Daniel Peterson, Geetanjali Gera, Fay B. Horak, Jessie M. Huisinga

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Objective To test the validity of wearable inertial sensors to provide objective measures of postural stepping responses to the push and release clinical test in people with multiple sclerosis. Design Cross-sectional study. Setting University medical center balance disorder laboratory. Participants Total sample N=73; persons with multiple sclerosis (PwMS) n=52; healthy controls n=21. Main Outcome Measures Stepping latency, time and number of steps required to reach stability, and initial step length were calculated using 3 inertial measurement units placed on participants' lumbar spine and feet. Results Correlations between inertial sensor measures and measures obtained from the laboratory-based systems were moderate to strong and statistically significant for all variables: time to release (r=.992), latency (r=.655), time to stability (r=.847), time of first heel strike (r=.665), number of steps (r=.825), and first step length (r=.592). Compared with healthy controls, PwMS demonstrated a longer time to stability and required a larger number of steps to reach stability. Conclusions The instrumented push and release test is a valid measure of postural responses in PwMS and could be used as a clinical outcome measures for patient care decisions or for clinical trials aimed at improving postural control in PwMS.

Original languageEnglish (US)
Pages (from-to)1325-1331
Number of pages7
JournalArchives of Physical Medicine and Rehabilitation
Volume98
Issue number7
DOIs
StatePublished - Jul 1 2017

Fingerprint

Multiple Sclerosis
Outcome Assessment (Health Care)
Heel
Foot
Patient Care
Spine
Cross-Sectional Studies
Clinical Trials

Keywords

  • Movement disorders
  • Multiple sclerosis
  • Rehabilitation

ASJC Scopus subject areas

  • Physical Therapy, Sports Therapy and Rehabilitation
  • Rehabilitation

Cite this

Validity of the Instrumented Push and Release Test to Quantify Postural Responses in Persons With Multiple Sclerosis. / El-Gohary, Mahmoud; Peterson, Daniel; Gera, Geetanjali; Horak, Fay B.; Huisinga, Jessie M.

In: Archives of Physical Medicine and Rehabilitation, Vol. 98, No. 7, 01.07.2017, p. 1325-1331.

Research output: Contribution to journalArticle

El-Gohary, Mahmoud ; Peterson, Daniel ; Gera, Geetanjali ; Horak, Fay B. ; Huisinga, Jessie M. / Validity of the Instrumented Push and Release Test to Quantify Postural Responses in Persons With Multiple Sclerosis. In: Archives of Physical Medicine and Rehabilitation. 2017 ; Vol. 98, No. 7. pp. 1325-1331.
@article{5a1a321c1a9e48e7b1b5a9d14f939fd2,
title = "Validity of the Instrumented Push and Release Test to Quantify Postural Responses in Persons With Multiple Sclerosis",
abstract = "Objective To test the validity of wearable inertial sensors to provide objective measures of postural stepping responses to the push and release clinical test in people with multiple sclerosis. Design Cross-sectional study. Setting University medical center balance disorder laboratory. Participants Total sample N=73; persons with multiple sclerosis (PwMS) n=52; healthy controls n=21. Main Outcome Measures Stepping latency, time and number of steps required to reach stability, and initial step length were calculated using 3 inertial measurement units placed on participants' lumbar spine and feet. Results Correlations between inertial sensor measures and measures obtained from the laboratory-based systems were moderate to strong and statistically significant for all variables: time to release (r=.992), latency (r=.655), time to stability (r=.847), time of first heel strike (r=.665), number of steps (r=.825), and first step length (r=.592). Compared with healthy controls, PwMS demonstrated a longer time to stability and required a larger number of steps to reach stability. Conclusions The instrumented push and release test is a valid measure of postural responses in PwMS and could be used as a clinical outcome measures for patient care decisions or for clinical trials aimed at improving postural control in PwMS.",
keywords = "Movement disorders, Multiple sclerosis, Rehabilitation",
author = "Mahmoud El-Gohary and Daniel Peterson and Geetanjali Gera and Horak, {Fay B.} and Huisinga, {Jessie M.}",
year = "2017",
month = "7",
day = "1",
doi = "10.1016/j.apmr.2017.01.030",
language = "English (US)",
volume = "98",
pages = "1325--1331",
journal = "Archives of Physical Medicine and Rehabilitation",
issn = "0003-9993",
publisher = "W.B. Saunders Ltd",
number = "7",

}

TY - JOUR

T1 - Validity of the Instrumented Push and Release Test to Quantify Postural Responses in Persons With Multiple Sclerosis

AU - El-Gohary, Mahmoud

AU - Peterson, Daniel

AU - Gera, Geetanjali

AU - Horak, Fay B.

AU - Huisinga, Jessie M.

PY - 2017/7/1

Y1 - 2017/7/1

N2 - Objective To test the validity of wearable inertial sensors to provide objective measures of postural stepping responses to the push and release clinical test in people with multiple sclerosis. Design Cross-sectional study. Setting University medical center balance disorder laboratory. Participants Total sample N=73; persons with multiple sclerosis (PwMS) n=52; healthy controls n=21. Main Outcome Measures Stepping latency, time and number of steps required to reach stability, and initial step length were calculated using 3 inertial measurement units placed on participants' lumbar spine and feet. Results Correlations between inertial sensor measures and measures obtained from the laboratory-based systems were moderate to strong and statistically significant for all variables: time to release (r=.992), latency (r=.655), time to stability (r=.847), time of first heel strike (r=.665), number of steps (r=.825), and first step length (r=.592). Compared with healthy controls, PwMS demonstrated a longer time to stability and required a larger number of steps to reach stability. Conclusions The instrumented push and release test is a valid measure of postural responses in PwMS and could be used as a clinical outcome measures for patient care decisions or for clinical trials aimed at improving postural control in PwMS.

AB - Objective To test the validity of wearable inertial sensors to provide objective measures of postural stepping responses to the push and release clinical test in people with multiple sclerosis. Design Cross-sectional study. Setting University medical center balance disorder laboratory. Participants Total sample N=73; persons with multiple sclerosis (PwMS) n=52; healthy controls n=21. Main Outcome Measures Stepping latency, time and number of steps required to reach stability, and initial step length were calculated using 3 inertial measurement units placed on participants' lumbar spine and feet. Results Correlations between inertial sensor measures and measures obtained from the laboratory-based systems were moderate to strong and statistically significant for all variables: time to release (r=.992), latency (r=.655), time to stability (r=.847), time of first heel strike (r=.665), number of steps (r=.825), and first step length (r=.592). Compared with healthy controls, PwMS demonstrated a longer time to stability and required a larger number of steps to reach stability. Conclusions The instrumented push and release test is a valid measure of postural responses in PwMS and could be used as a clinical outcome measures for patient care decisions or for clinical trials aimed at improving postural control in PwMS.

KW - Movement disorders

KW - Multiple sclerosis

KW - Rehabilitation

UR - http://www.scopus.com/inward/record.url?scp=85018322870&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85018322870&partnerID=8YFLogxK

U2 - 10.1016/j.apmr.2017.01.030

DO - 10.1016/j.apmr.2017.01.030

M3 - Article

VL - 98

SP - 1325

EP - 1331

JO - Archives of Physical Medicine and Rehabilitation

JF - Archives of Physical Medicine and Rehabilitation

SN - 0003-9993

IS - 7

ER -