VALIDATION OF THE POLYURETHANE FOAM ROOF SYSTEM.

D. Kashiwagi, W. C. Moor

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Sprayed 'IN PLACE' polyurethane foam (PUF) roof systems have been installed since the early 1960's. The lack of clear systems definition and requirements based on field performance of 'successful' (20 year service life) PUF roofs, and an unbiased database of PUF roof failures and successes have resulted in the continuing unpredictability of PUF roof performance. The objective of this study is to define the PUF roof system, performance requirements and component requirements. The results will be used to define the PUF roof system performance criteria.

Original languageEnglish (US)
Pages (from-to)91-110
Number of pages20
JournalJournal of Thermal Insulation
Volume10
StatePublished - Oct 1986
Externally publishedYes

Fingerprint

Roofs
Polyurethanes
Foams
Service life
polyurethane foam

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Kashiwagi, D., & Moor, W. C. (1986). VALIDATION OF THE POLYURETHANE FOAM ROOF SYSTEM. Journal of Thermal Insulation, 10, 91-110.

VALIDATION OF THE POLYURETHANE FOAM ROOF SYSTEM. / Kashiwagi, D.; Moor, W. C.

In: Journal of Thermal Insulation, Vol. 10, 10.1986, p. 91-110.

Research output: Contribution to journalArticle

Kashiwagi, D & Moor, WC 1986, 'VALIDATION OF THE POLYURETHANE FOAM ROOF SYSTEM.', Journal of Thermal Insulation, vol. 10, pp. 91-110.
Kashiwagi, D. ; Moor, W. C. / VALIDATION OF THE POLYURETHANE FOAM ROOF SYSTEM. In: Journal of Thermal Insulation. 1986 ; Vol. 10. pp. 91-110.
@article{920cd1d7dbe8476d8ad3a5b4f479bec9,
title = "VALIDATION OF THE POLYURETHANE FOAM ROOF SYSTEM.",
abstract = "Sprayed 'IN PLACE' polyurethane foam (PUF) roof systems have been installed since the early 1960's. The lack of clear systems definition and requirements based on field performance of 'successful' (20 year service life) PUF roofs, and an unbiased database of PUF roof failures and successes have resulted in the continuing unpredictability of PUF roof performance. The objective of this study is to define the PUF roof system, performance requirements and component requirements. The results will be used to define the PUF roof system performance criteria.",
author = "D. Kashiwagi and Moor, {W. C.}",
year = "1986",
month = "10",
language = "English (US)",
volume = "10",
pages = "91--110",
journal = "Journal of Building Physics",
issn = "1744-2591",
publisher = "SAGE Publications Ltd",

}

TY - JOUR

T1 - VALIDATION OF THE POLYURETHANE FOAM ROOF SYSTEM.

AU - Kashiwagi, D.

AU - Moor, W. C.

PY - 1986/10

Y1 - 1986/10

N2 - Sprayed 'IN PLACE' polyurethane foam (PUF) roof systems have been installed since the early 1960's. The lack of clear systems definition and requirements based on field performance of 'successful' (20 year service life) PUF roofs, and an unbiased database of PUF roof failures and successes have resulted in the continuing unpredictability of PUF roof performance. The objective of this study is to define the PUF roof system, performance requirements and component requirements. The results will be used to define the PUF roof system performance criteria.

AB - Sprayed 'IN PLACE' polyurethane foam (PUF) roof systems have been installed since the early 1960's. The lack of clear systems definition and requirements based on field performance of 'successful' (20 year service life) PUF roofs, and an unbiased database of PUF roof failures and successes have resulted in the continuing unpredictability of PUF roof performance. The objective of this study is to define the PUF roof system, performance requirements and component requirements. The results will be used to define the PUF roof system performance criteria.

UR - http://www.scopus.com/inward/record.url?scp=0022803061&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022803061&partnerID=8YFLogxK

M3 - Article

VL - 10

SP - 91

EP - 110

JO - Journal of Building Physics

JF - Journal of Building Physics

SN - 1744-2591