Abstract

Engineered, natural or incidental colloidal-sized materials in tap water may originate from source water or be generated in distribution systems (e.g., corrosion-related). An optimized single-particle (sp)-ICP-MS technique was applied to tap water samples (n = 50) collected from three buildings to analyze for Pb, Fe, Sn, Cu, Ag and Ti-containing particles. The Pb, Sn and Fe-containing particles were detected at an average concentration (ng L-1) of 1.2 (range: 0.06-4.8), 1.8 (range: 0.11-14), and 88 (range: 26-890), respectively, representing the corresponding total dissolved metal concentrations at a minimum of 0.4%, 10%, and 15%. No particulate Ti and Ag were observed in the samples. The Pb concentrations in the first 125 mL fraction collected were on average three times higher than those in the subsequent samples. Detection of the Cu particles required modification of the sample introduction system (direct self-aspiration into the nebulizer) to reduce matrix interaction with the auto-sampler tubing. The Cu particles were detected in 50% of the analyzed samples at an average concentration of 69 (range: 15-136) ng L-1. While all the metal concentrations were below the health advisory levels, this study showcases the feasibility and first application of spICP-MS to monitor metal-containing particles in tap waters, and the results suggest that the particulate forms of the studied elements may represent a significant fraction of the bulk elemental concentration in tap water.

Original languageEnglish (US)
Pages (from-to)1923-1932
Number of pages10
JournalEnvironmental Science: Water Research and Technology
Volume4
Issue number12
DOIs
StatePublished - Dec 1 2018

Fingerprint

Monitoring
metal
monitoring
Metals
Water
water
Tubing
distribution system
sampler
particle
Health
corrosion
Corrosion
matrix

ASJC Scopus subject areas

  • Environmental Engineering
  • Water Science and Technology

Cite this

Using single-particle ICP-MS for monitoring metal-containing particles in tap water. / Venkatesan, Arjun K.; Rodríguez, Blanca T.; Marcotte, Aurelie R.; Bi, Xiangyu; Schoepf, Jared; Ranville, James F.; Herckes, Pierre; Westerhoff, Paul.

In: Environmental Science: Water Research and Technology, Vol. 4, No. 12, 01.12.2018, p. 1923-1932.

Research output: Contribution to journalArticle

Venkatesan, Arjun K. ; Rodríguez, Blanca T. ; Marcotte, Aurelie R. ; Bi, Xiangyu ; Schoepf, Jared ; Ranville, James F. ; Herckes, Pierre ; Westerhoff, Paul. / Using single-particle ICP-MS for monitoring metal-containing particles in tap water. In: Environmental Science: Water Research and Technology. 2018 ; Vol. 4, No. 12. pp. 1923-1932.
@article{89ebdb1f936e44d09312be37cdc4825d,
title = "Using single-particle ICP-MS for monitoring metal-containing particles in tap water",
abstract = "Engineered, natural or incidental colloidal-sized materials in tap water may originate from source water or be generated in distribution systems (e.g., corrosion-related). An optimized single-particle (sp)-ICP-MS technique was applied to tap water samples (n = 50) collected from three buildings to analyze for Pb, Fe, Sn, Cu, Ag and Ti-containing particles. The Pb, Sn and Fe-containing particles were detected at an average concentration (ng L-1) of 1.2 (range: 0.06-4.8), 1.8 (range: 0.11-14), and 88 (range: 26-890), respectively, representing the corresponding total dissolved metal concentrations at a minimum of 0.4{\%}, 10{\%}, and 15{\%}. No particulate Ti and Ag were observed in the samples. The Pb concentrations in the first 125 mL fraction collected were on average three times higher than those in the subsequent samples. Detection of the Cu particles required modification of the sample introduction system (direct self-aspiration into the nebulizer) to reduce matrix interaction with the auto-sampler tubing. The Cu particles were detected in 50{\%} of the analyzed samples at an average concentration of 69 (range: 15-136) ng L-1. While all the metal concentrations were below the health advisory levels, this study showcases the feasibility and first application of spICP-MS to monitor metal-containing particles in tap waters, and the results suggest that the particulate forms of the studied elements may represent a significant fraction of the bulk elemental concentration in tap water.",
author = "Venkatesan, {Arjun K.} and Rodr{\'i}guez, {Blanca T.} and Marcotte, {Aurelie R.} and Xiangyu Bi and Jared Schoepf and Ranville, {James F.} and Pierre Herckes and Paul Westerhoff",
year = "2018",
month = "12",
day = "1",
doi = "10.1039/c8ew00478a",
language = "English (US)",
volume = "4",
pages = "1923--1932",
journal = "Environmental Science: Water Research and Technology",
issn = "2053-1400",
publisher = "Royal Society of Chemistry",
number = "12",

}

TY - JOUR

T1 - Using single-particle ICP-MS for monitoring metal-containing particles in tap water

AU - Venkatesan, Arjun K.

AU - Rodríguez, Blanca T.

AU - Marcotte, Aurelie R.

AU - Bi, Xiangyu

AU - Schoepf, Jared

AU - Ranville, James F.

AU - Herckes, Pierre

AU - Westerhoff, Paul

PY - 2018/12/1

Y1 - 2018/12/1

N2 - Engineered, natural or incidental colloidal-sized materials in tap water may originate from source water or be generated in distribution systems (e.g., corrosion-related). An optimized single-particle (sp)-ICP-MS technique was applied to tap water samples (n = 50) collected from three buildings to analyze for Pb, Fe, Sn, Cu, Ag and Ti-containing particles. The Pb, Sn and Fe-containing particles were detected at an average concentration (ng L-1) of 1.2 (range: 0.06-4.8), 1.8 (range: 0.11-14), and 88 (range: 26-890), respectively, representing the corresponding total dissolved metal concentrations at a minimum of 0.4%, 10%, and 15%. No particulate Ti and Ag were observed in the samples. The Pb concentrations in the first 125 mL fraction collected were on average three times higher than those in the subsequent samples. Detection of the Cu particles required modification of the sample introduction system (direct self-aspiration into the nebulizer) to reduce matrix interaction with the auto-sampler tubing. The Cu particles were detected in 50% of the analyzed samples at an average concentration of 69 (range: 15-136) ng L-1. While all the metal concentrations were below the health advisory levels, this study showcases the feasibility and first application of spICP-MS to monitor metal-containing particles in tap waters, and the results suggest that the particulate forms of the studied elements may represent a significant fraction of the bulk elemental concentration in tap water.

AB - Engineered, natural or incidental colloidal-sized materials in tap water may originate from source water or be generated in distribution systems (e.g., corrosion-related). An optimized single-particle (sp)-ICP-MS technique was applied to tap water samples (n = 50) collected from three buildings to analyze for Pb, Fe, Sn, Cu, Ag and Ti-containing particles. The Pb, Sn and Fe-containing particles were detected at an average concentration (ng L-1) of 1.2 (range: 0.06-4.8), 1.8 (range: 0.11-14), and 88 (range: 26-890), respectively, representing the corresponding total dissolved metal concentrations at a minimum of 0.4%, 10%, and 15%. No particulate Ti and Ag were observed in the samples. The Pb concentrations in the first 125 mL fraction collected were on average three times higher than those in the subsequent samples. Detection of the Cu particles required modification of the sample introduction system (direct self-aspiration into the nebulizer) to reduce matrix interaction with the auto-sampler tubing. The Cu particles were detected in 50% of the analyzed samples at an average concentration of 69 (range: 15-136) ng L-1. While all the metal concentrations were below the health advisory levels, this study showcases the feasibility and first application of spICP-MS to monitor metal-containing particles in tap waters, and the results suggest that the particulate forms of the studied elements may represent a significant fraction of the bulk elemental concentration in tap water.

UR - http://www.scopus.com/inward/record.url?scp=85057389183&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85057389183&partnerID=8YFLogxK

U2 - 10.1039/c8ew00478a

DO - 10.1039/c8ew00478a

M3 - Article

VL - 4

SP - 1923

EP - 1932

JO - Environmental Science: Water Research and Technology

JF - Environmental Science: Water Research and Technology

SN - 2053-1400

IS - 12

ER -