Transmission line parameter identification using PMU measurements

Di Shi, Daniel Tylavsky, Kristian M. Koellner, Naim Logic, David E. Wheeler

Research output: Contribution to journalArticle

49 Citations (Scopus)

Abstract

Accurate knowledge of transmission line (TL) impedance parameters helps to improve accuracy in relay settings and power flow modeling. To improve TL parameter estimates, various algorithms have been proposed in the past to identify TL parameters based on measurements from Phasor Measurement Units (PMUs). These methods are based on the positive sequence TL models and can generate accurate positive sequence impedance parameters for a fully transposed TL when measurement noise is absent; however, these methods may generate erroneous parameters when the TLs are not fully transposed or when measurement noise is present. PMU field-measure data are often corrupted with noise and this noise is problematic for all parameter identification algorithms, particularly so when applied to short TLs. This paper analyzes the limitations of the positive sequence TL model when used for parameter estimation of TLs that are untransposed and proposes a novel method using linear estimation theory to identify TL parameters more reliably. This method can be used for the most general case: short/long lines that are fully transposed or untransposed and have balanced/unbalance loads. Besides the positive/negative sequence impedance parameters, the proposed method can also be used to estimate the zero sequence parameters and the mutual impedances between different sequences. This paper also examines the influence of noise in the PMU data on the calculation of TL parameters. Several case studies are conducted based on simulated data from ATP to validate the effectiveness of the new method. Through comparison of the results generated by this novel method and several other methods, the effectiveness of the proposed approach is demonstrated.

Original languageEnglish (US)
Pages (from-to)1574-1588
Number of pages15
JournalEuropean Transactions on Electrical Power
Volume21
Issue number4
DOIs
StatePublished - May 2011

Fingerprint

Phasor measurement units
Parameter Identification
Transmission Line
Electric lines
Identification (control systems)
Unit
Impedance
Estimation Theory
Linear Estimation
Adenosinetriphosphate
Measure Data
Power Flow
Parameter estimation
Estimate
Relay
Parameter Estimation

Keywords

  • GPS-synchronized phasor measurement
  • linear estimation theory
  • PMU
  • positive sequence transmission line model
  • transmission line impedance parameters

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Energy Engineering and Power Technology

Cite this

Transmission line parameter identification using PMU measurements. / Shi, Di; Tylavsky, Daniel; Koellner, Kristian M.; Logic, Naim; Wheeler, David E.

In: European Transactions on Electrical Power, Vol. 21, No. 4, 05.2011, p. 1574-1588.

Research output: Contribution to journalArticle

Shi, Di ; Tylavsky, Daniel ; Koellner, Kristian M. ; Logic, Naim ; Wheeler, David E. / Transmission line parameter identification using PMU measurements. In: European Transactions on Electrical Power. 2011 ; Vol. 21, No. 4. pp. 1574-1588.
@article{6ffd48d9133842d0b9786404070ed50d,
title = "Transmission line parameter identification using PMU measurements",
abstract = "Accurate knowledge of transmission line (TL) impedance parameters helps to improve accuracy in relay settings and power flow modeling. To improve TL parameter estimates, various algorithms have been proposed in the past to identify TL parameters based on measurements from Phasor Measurement Units (PMUs). These methods are based on the positive sequence TL models and can generate accurate positive sequence impedance parameters for a fully transposed TL when measurement noise is absent; however, these methods may generate erroneous parameters when the TLs are not fully transposed or when measurement noise is present. PMU field-measure data are often corrupted with noise and this noise is problematic for all parameter identification algorithms, particularly so when applied to short TLs. This paper analyzes the limitations of the positive sequence TL model when used for parameter estimation of TLs that are untransposed and proposes a novel method using linear estimation theory to identify TL parameters more reliably. This method can be used for the most general case: short/long lines that are fully transposed or untransposed and have balanced/unbalance loads. Besides the positive/negative sequence impedance parameters, the proposed method can also be used to estimate the zero sequence parameters and the mutual impedances between different sequences. This paper also examines the influence of noise in the PMU data on the calculation of TL parameters. Several case studies are conducted based on simulated data from ATP to validate the effectiveness of the new method. Through comparison of the results generated by this novel method and several other methods, the effectiveness of the proposed approach is demonstrated.",
keywords = "GPS-synchronized phasor measurement, linear estimation theory, PMU, positive sequence transmission line model, transmission line impedance parameters",
author = "Di Shi and Daniel Tylavsky and Koellner, {Kristian M.} and Naim Logic and Wheeler, {David E.}",
year = "2011",
month = "5",
doi = "10.1002/etep.522",
language = "English (US)",
volume = "21",
pages = "1574--1588",
journal = "International Transactions on Electrical Energy Systems",
issn = "1430-144X",
publisher = "John Wiley and Sons Ltd",
number = "4",

}

TY - JOUR

T1 - Transmission line parameter identification using PMU measurements

AU - Shi, Di

AU - Tylavsky, Daniel

AU - Koellner, Kristian M.

AU - Logic, Naim

AU - Wheeler, David E.

PY - 2011/5

Y1 - 2011/5

N2 - Accurate knowledge of transmission line (TL) impedance parameters helps to improve accuracy in relay settings and power flow modeling. To improve TL parameter estimates, various algorithms have been proposed in the past to identify TL parameters based on measurements from Phasor Measurement Units (PMUs). These methods are based on the positive sequence TL models and can generate accurate positive sequence impedance parameters for a fully transposed TL when measurement noise is absent; however, these methods may generate erroneous parameters when the TLs are not fully transposed or when measurement noise is present. PMU field-measure data are often corrupted with noise and this noise is problematic for all parameter identification algorithms, particularly so when applied to short TLs. This paper analyzes the limitations of the positive sequence TL model when used for parameter estimation of TLs that are untransposed and proposes a novel method using linear estimation theory to identify TL parameters more reliably. This method can be used for the most general case: short/long lines that are fully transposed or untransposed and have balanced/unbalance loads. Besides the positive/negative sequence impedance parameters, the proposed method can also be used to estimate the zero sequence parameters and the mutual impedances between different sequences. This paper also examines the influence of noise in the PMU data on the calculation of TL parameters. Several case studies are conducted based on simulated data from ATP to validate the effectiveness of the new method. Through comparison of the results generated by this novel method and several other methods, the effectiveness of the proposed approach is demonstrated.

AB - Accurate knowledge of transmission line (TL) impedance parameters helps to improve accuracy in relay settings and power flow modeling. To improve TL parameter estimates, various algorithms have been proposed in the past to identify TL parameters based on measurements from Phasor Measurement Units (PMUs). These methods are based on the positive sequence TL models and can generate accurate positive sequence impedance parameters for a fully transposed TL when measurement noise is absent; however, these methods may generate erroneous parameters when the TLs are not fully transposed or when measurement noise is present. PMU field-measure data are often corrupted with noise and this noise is problematic for all parameter identification algorithms, particularly so when applied to short TLs. This paper analyzes the limitations of the positive sequence TL model when used for parameter estimation of TLs that are untransposed and proposes a novel method using linear estimation theory to identify TL parameters more reliably. This method can be used for the most general case: short/long lines that are fully transposed or untransposed and have balanced/unbalance loads. Besides the positive/negative sequence impedance parameters, the proposed method can also be used to estimate the zero sequence parameters and the mutual impedances between different sequences. This paper also examines the influence of noise in the PMU data on the calculation of TL parameters. Several case studies are conducted based on simulated data from ATP to validate the effectiveness of the new method. Through comparison of the results generated by this novel method and several other methods, the effectiveness of the proposed approach is demonstrated.

KW - GPS-synchronized phasor measurement

KW - linear estimation theory

KW - PMU

KW - positive sequence transmission line model

KW - transmission line impedance parameters

UR - http://www.scopus.com/inward/record.url?scp=79957483538&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79957483538&partnerID=8YFLogxK

U2 - 10.1002/etep.522

DO - 10.1002/etep.522

M3 - Article

VL - 21

SP - 1574

EP - 1588

JO - International Transactions on Electrical Energy Systems

JF - International Transactions on Electrical Energy Systems

SN - 1430-144X

IS - 4

ER -