Thoracic size-selective sampling of fibres: Performance of four types of thoracic sampler in laboratory tests

A. D. Jones, R. J. Aitken, J. F. Fabriès, E. Kauffer, G. Liden, Andrew Maynard, G. Riediger, W. Sahle

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

The counting of fibres on membrane filters could be facilitated by using size-selective samplers to exclude coarse particulate and fibres that impede fibre counting. Furthermore, the use of thoracic size selection would also remove the present requirement to discriminate fibres by diameter during counting. However, before thoracic samplers become acceptable for sampling fibres, their performance with fibres needs to be determined. This study examines the performance of four thoracic samplers: the GK2.69 cyclone, a Modified SIMPEDS cyclone, the CATHIA sampler (inertial separation) and the IOM thoracic sampler (porous foam pre-selector). The uniformity of sample deposit on the filter samples, which is important when counts are taken on random fields, was examined with two sizes of spherical particles (1 and 10 μm) and a glass fibre aerosol with fibres spanning the aerodynamic size range of the thoracic convention. Counts by optical microscopy examined fields on a set scanning pattern. Hotspots of deposition were detected for one of the thoracic samplers (Modified SIMPEDS with the 10 μm particles and the fibres). These hotspots were attributed to the inertial flow pattern near the port from the cyclone pre-separator. For the other three thoracic samplers, the distribution was similar to that on a cowled sampler, the current standard sampler for fibres. Aerodynamic selection was examined by comparing fibre concentration on thoracic samples with those measured on semi-isokinetic samples, using fibre size (and hence calculated aerodynamic diameter) and number data obtained by scanning electron microscope evaluation in four laboratories. The size-selection characteristics of three thoracic samplers (GK2.69, Modified SIMPEDS and CATHIA) appeared very similar to the thoracic convention; there was a slight oversampling (relative to the convention) for dae <7 μm, but that would not be disadvantageous for comparability with the cowled sampler. Only the IOM thoracic sampler tended to undersample the fibres relative to the thoracic convention. With the data divided into four classes based on fibre length, the size-selection characteristics appeared to be unaffected by fibre length for GK2.69, Modified SIMPEDS and CATHIA. Only the IOM thoracic sampler (with the foam selector) showed slightly lower selection for longer length classes of fibres. These results indicate that the tested samplers follow the thoracic sampling convention for fibres, and may be used to improve the quality and reliability of samples that are taken when there is likely to be significant background dust.

Original languageEnglish (US)
Pages (from-to)481-492
Number of pages12
JournalAnnals of Occupational Hygiene
Volume49
Issue number6
DOIs
StatePublished - Aug 2005
Externally publishedYes

Fingerprint

Thorax
Cyclonic Storms
Aerosols
Dust
Particle Size
Microscopy
Electrons
Membranes

Keywords

  • Fibres
  • Sampling
  • Size-selective
  • Thoracic

ASJC Scopus subject areas

  • Public Health, Environmental and Occupational Health
  • Health Professions(all)

Cite this

Thoracic size-selective sampling of fibres : Performance of four types of thoracic sampler in laboratory tests. / Jones, A. D.; Aitken, R. J.; Fabriès, J. F.; Kauffer, E.; Liden, G.; Maynard, Andrew; Riediger, G.; Sahle, W.

In: Annals of Occupational Hygiene, Vol. 49, No. 6, 08.2005, p. 481-492.

Research output: Contribution to journalArticle

Jones, A. D. ; Aitken, R. J. ; Fabriès, J. F. ; Kauffer, E. ; Liden, G. ; Maynard, Andrew ; Riediger, G. ; Sahle, W. / Thoracic size-selective sampling of fibres : Performance of four types of thoracic sampler in laboratory tests. In: Annals of Occupational Hygiene. 2005 ; Vol. 49, No. 6. pp. 481-492.
@article{2115c31743cb48f79372bbdb2eb62a22,
title = "Thoracic size-selective sampling of fibres: Performance of four types of thoracic sampler in laboratory tests",
abstract = "The counting of fibres on membrane filters could be facilitated by using size-selective samplers to exclude coarse particulate and fibres that impede fibre counting. Furthermore, the use of thoracic size selection would also remove the present requirement to discriminate fibres by diameter during counting. However, before thoracic samplers become acceptable for sampling fibres, their performance with fibres needs to be determined. This study examines the performance of four thoracic samplers: the GK2.69 cyclone, a Modified SIMPEDS cyclone, the CATHIA sampler (inertial separation) and the IOM thoracic sampler (porous foam pre-selector). The uniformity of sample deposit on the filter samples, which is important when counts are taken on random fields, was examined with two sizes of spherical particles (1 and 10 μm) and a glass fibre aerosol with fibres spanning the aerodynamic size range of the thoracic convention. Counts by optical microscopy examined fields on a set scanning pattern. Hotspots of deposition were detected for one of the thoracic samplers (Modified SIMPEDS with the 10 μm particles and the fibres). These hotspots were attributed to the inertial flow pattern near the port from the cyclone pre-separator. For the other three thoracic samplers, the distribution was similar to that on a cowled sampler, the current standard sampler for fibres. Aerodynamic selection was examined by comparing fibre concentration on thoracic samples with those measured on semi-isokinetic samples, using fibre size (and hence calculated aerodynamic diameter) and number data obtained by scanning electron microscope evaluation in four laboratories. The size-selection characteristics of three thoracic samplers (GK2.69, Modified SIMPEDS and CATHIA) appeared very similar to the thoracic convention; there was a slight oversampling (relative to the convention) for dae <7 μm, but that would not be disadvantageous for comparability with the cowled sampler. Only the IOM thoracic sampler tended to undersample the fibres relative to the thoracic convention. With the data divided into four classes based on fibre length, the size-selection characteristics appeared to be unaffected by fibre length for GK2.69, Modified SIMPEDS and CATHIA. Only the IOM thoracic sampler (with the foam selector) showed slightly lower selection for longer length classes of fibres. These results indicate that the tested samplers follow the thoracic sampling convention for fibres, and may be used to improve the quality and reliability of samples that are taken when there is likely to be significant background dust.",
keywords = "Fibres, Sampling, Size-selective, Thoracic",
author = "Jones, {A. D.} and Aitken, {R. J.} and Fabri{\`e}s, {J. F.} and E. Kauffer and G. Liden and Andrew Maynard and G. Riediger and W. Sahle",
year = "2005",
month = "8",
doi = "10.1093/annhyg/mei004",
language = "English (US)",
volume = "49",
pages = "481--492",
journal = "Annals of Work Exposures and Health",
issn = "2398-7308",
publisher = "Oxford University Press",
number = "6",

}

TY - JOUR

T1 - Thoracic size-selective sampling of fibres

T2 - Performance of four types of thoracic sampler in laboratory tests

AU - Jones, A. D.

AU - Aitken, R. J.

AU - Fabriès, J. F.

AU - Kauffer, E.

AU - Liden, G.

AU - Maynard, Andrew

AU - Riediger, G.

AU - Sahle, W.

PY - 2005/8

Y1 - 2005/8

N2 - The counting of fibres on membrane filters could be facilitated by using size-selective samplers to exclude coarse particulate and fibres that impede fibre counting. Furthermore, the use of thoracic size selection would also remove the present requirement to discriminate fibres by diameter during counting. However, before thoracic samplers become acceptable for sampling fibres, their performance with fibres needs to be determined. This study examines the performance of four thoracic samplers: the GK2.69 cyclone, a Modified SIMPEDS cyclone, the CATHIA sampler (inertial separation) and the IOM thoracic sampler (porous foam pre-selector). The uniformity of sample deposit on the filter samples, which is important when counts are taken on random fields, was examined with two sizes of spherical particles (1 and 10 μm) and a glass fibre aerosol with fibres spanning the aerodynamic size range of the thoracic convention. Counts by optical microscopy examined fields on a set scanning pattern. Hotspots of deposition were detected for one of the thoracic samplers (Modified SIMPEDS with the 10 μm particles and the fibres). These hotspots were attributed to the inertial flow pattern near the port from the cyclone pre-separator. For the other three thoracic samplers, the distribution was similar to that on a cowled sampler, the current standard sampler for fibres. Aerodynamic selection was examined by comparing fibre concentration on thoracic samples with those measured on semi-isokinetic samples, using fibre size (and hence calculated aerodynamic diameter) and number data obtained by scanning electron microscope evaluation in four laboratories. The size-selection characteristics of three thoracic samplers (GK2.69, Modified SIMPEDS and CATHIA) appeared very similar to the thoracic convention; there was a slight oversampling (relative to the convention) for dae <7 μm, but that would not be disadvantageous for comparability with the cowled sampler. Only the IOM thoracic sampler tended to undersample the fibres relative to the thoracic convention. With the data divided into four classes based on fibre length, the size-selection characteristics appeared to be unaffected by fibre length for GK2.69, Modified SIMPEDS and CATHIA. Only the IOM thoracic sampler (with the foam selector) showed slightly lower selection for longer length classes of fibres. These results indicate that the tested samplers follow the thoracic sampling convention for fibres, and may be used to improve the quality and reliability of samples that are taken when there is likely to be significant background dust.

AB - The counting of fibres on membrane filters could be facilitated by using size-selective samplers to exclude coarse particulate and fibres that impede fibre counting. Furthermore, the use of thoracic size selection would also remove the present requirement to discriminate fibres by diameter during counting. However, before thoracic samplers become acceptable for sampling fibres, their performance with fibres needs to be determined. This study examines the performance of four thoracic samplers: the GK2.69 cyclone, a Modified SIMPEDS cyclone, the CATHIA sampler (inertial separation) and the IOM thoracic sampler (porous foam pre-selector). The uniformity of sample deposit on the filter samples, which is important when counts are taken on random fields, was examined with two sizes of spherical particles (1 and 10 μm) and a glass fibre aerosol with fibres spanning the aerodynamic size range of the thoracic convention. Counts by optical microscopy examined fields on a set scanning pattern. Hotspots of deposition were detected for one of the thoracic samplers (Modified SIMPEDS with the 10 μm particles and the fibres). These hotspots were attributed to the inertial flow pattern near the port from the cyclone pre-separator. For the other three thoracic samplers, the distribution was similar to that on a cowled sampler, the current standard sampler for fibres. Aerodynamic selection was examined by comparing fibre concentration on thoracic samples with those measured on semi-isokinetic samples, using fibre size (and hence calculated aerodynamic diameter) and number data obtained by scanning electron microscope evaluation in four laboratories. The size-selection characteristics of three thoracic samplers (GK2.69, Modified SIMPEDS and CATHIA) appeared very similar to the thoracic convention; there was a slight oversampling (relative to the convention) for dae <7 μm, but that would not be disadvantageous for comparability with the cowled sampler. Only the IOM thoracic sampler tended to undersample the fibres relative to the thoracic convention. With the data divided into four classes based on fibre length, the size-selection characteristics appeared to be unaffected by fibre length for GK2.69, Modified SIMPEDS and CATHIA. Only the IOM thoracic sampler (with the foam selector) showed slightly lower selection for longer length classes of fibres. These results indicate that the tested samplers follow the thoracic sampling convention for fibres, and may be used to improve the quality and reliability of samples that are taken when there is likely to be significant background dust.

KW - Fibres

KW - Sampling

KW - Size-selective

KW - Thoracic

UR - http://www.scopus.com/inward/record.url?scp=23944489929&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=23944489929&partnerID=8YFLogxK

U2 - 10.1093/annhyg/mei004

DO - 10.1093/annhyg/mei004

M3 - Article

C2 - 15790615

AN - SCOPUS:23944489929

VL - 49

SP - 481

EP - 492

JO - Annals of Work Exposures and Health

JF - Annals of Work Exposures and Health

SN - 2398-7308

IS - 6

ER -