Abstract
Measurement and control of the high T variable is necessary in high P synthesis and in situ experiments. We introduce concepts of heat and temperature and how to apply and measure them in high P environments using piston-cylinder and multi-anvil environments as examples. These are readily adapted to other types of high-pressure apparatus. We also describe the operation of the laser-heated diamond anvil cell.
Original language | English (US) |
---|---|
Title of host publication | High-Pressure Physics |
Publisher | CRC Press |
Pages | 223-243 |
Number of pages | 21 |
ISBN (Electronic) | 9781439814291 |
ISBN (Print) | 9781439814284 |
DOIs | |
State | Published - Jan 1 2012 |
ASJC Scopus subject areas
- General Physics and Astronomy
- General Engineering
- General Materials Science