Simulating the effect of cochlear-implant electrode insertion depth on speech understanding

Michael Dorman, Philipos C. Loizou, Dawne Rainey

    Research output: Contribution to journalArticle

    122 Citations (Scopus)

    Abstract

    Normally hearing listeners were presented with vowels, consonants, and sentences for identification through an acoustic simulation of a five- channel cochlear implant with electrodes separated by 4 mm (as in the Ineraid implant). The aim of the experiment was to simulate the effect of depth of electrode insertion on identification accuracy. Insertion depth was simulated by outputing sine waves from each channel of the processor at a frequency determined by the cochlear place of electrodes inserted 22-25 mm into the cochlea. The results indicate that simulated insertion depth had a significant effect on performance. Performance at 22- and 23-mm simulated insertion depths was always poorer than normal, and performance at 25-mm simulated insertion depth was, most generally, the same as normal. It is inferred from these results that, if insertion depth could be unconfounded from other coexisting factors in implant patients, then insertion depth would be found to affect speech identification performance significantly.

    Original languageEnglish (US)
    Pages (from-to)2993-2996
    Number of pages4
    JournalJournal of the Acoustical Society of America
    Volume102
    Issue number5 I
    DOIs
    StatePublished - Nov 1997

    Fingerprint

    insertion
    electrodes
    acoustic simulation
    cochlea
    sentences
    vowels
    sine waves
    hearing
    Cochlear Implant
    Insertion
    central processing units

    ASJC Scopus subject areas

    • Acoustics and Ultrasonics

    Cite this

    Simulating the effect of cochlear-implant electrode insertion depth on speech understanding. / Dorman, Michael; Loizou, Philipos C.; Rainey, Dawne.

    In: Journal of the Acoustical Society of America, Vol. 102, No. 5 I, 11.1997, p. 2993-2996.

    Research output: Contribution to journalArticle

    Dorman, Michael ; Loizou, Philipos C. ; Rainey, Dawne. / Simulating the effect of cochlear-implant electrode insertion depth on speech understanding. In: Journal of the Acoustical Society of America. 1997 ; Vol. 102, No. 5 I. pp. 2993-2996.
    @article{14d30587964040d58fce42929e9b092b,
    title = "Simulating the effect of cochlear-implant electrode insertion depth on speech understanding",
    abstract = "Normally hearing listeners were presented with vowels, consonants, and sentences for identification through an acoustic simulation of a five- channel cochlear implant with electrodes separated by 4 mm (as in the Ineraid implant). The aim of the experiment was to simulate the effect of depth of electrode insertion on identification accuracy. Insertion depth was simulated by outputing sine waves from each channel of the processor at a frequency determined by the cochlear place of electrodes inserted 22-25 mm into the cochlea. The results indicate that simulated insertion depth had a significant effect on performance. Performance at 22- and 23-mm simulated insertion depths was always poorer than normal, and performance at 25-mm simulated insertion depth was, most generally, the same as normal. It is inferred from these results that, if insertion depth could be unconfounded from other coexisting factors in implant patients, then insertion depth would be found to affect speech identification performance significantly.",
    author = "Michael Dorman and Loizou, {Philipos C.} and Dawne Rainey",
    year = "1997",
    month = "11",
    doi = "10.1121/1.420354",
    language = "English (US)",
    volume = "102",
    pages = "2993--2996",
    journal = "Journal of the Acoustical Society of America",
    issn = "0001-4966",
    publisher = "Acoustical Society of America",
    number = "5 I",

    }

    TY - JOUR

    T1 - Simulating the effect of cochlear-implant electrode insertion depth on speech understanding

    AU - Dorman, Michael

    AU - Loizou, Philipos C.

    AU - Rainey, Dawne

    PY - 1997/11

    Y1 - 1997/11

    N2 - Normally hearing listeners were presented with vowels, consonants, and sentences for identification through an acoustic simulation of a five- channel cochlear implant with electrodes separated by 4 mm (as in the Ineraid implant). The aim of the experiment was to simulate the effect of depth of electrode insertion on identification accuracy. Insertion depth was simulated by outputing sine waves from each channel of the processor at a frequency determined by the cochlear place of electrodes inserted 22-25 mm into the cochlea. The results indicate that simulated insertion depth had a significant effect on performance. Performance at 22- and 23-mm simulated insertion depths was always poorer than normal, and performance at 25-mm simulated insertion depth was, most generally, the same as normal. It is inferred from these results that, if insertion depth could be unconfounded from other coexisting factors in implant patients, then insertion depth would be found to affect speech identification performance significantly.

    AB - Normally hearing listeners were presented with vowels, consonants, and sentences for identification through an acoustic simulation of a five- channel cochlear implant with electrodes separated by 4 mm (as in the Ineraid implant). The aim of the experiment was to simulate the effect of depth of electrode insertion on identification accuracy. Insertion depth was simulated by outputing sine waves from each channel of the processor at a frequency determined by the cochlear place of electrodes inserted 22-25 mm into the cochlea. The results indicate that simulated insertion depth had a significant effect on performance. Performance at 22- and 23-mm simulated insertion depths was always poorer than normal, and performance at 25-mm simulated insertion depth was, most generally, the same as normal. It is inferred from these results that, if insertion depth could be unconfounded from other coexisting factors in implant patients, then insertion depth would be found to affect speech identification performance significantly.

    UR - http://www.scopus.com/inward/record.url?scp=0030662183&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0030662183&partnerID=8YFLogxK

    U2 - 10.1121/1.420354

    DO - 10.1121/1.420354

    M3 - Article

    C2 - 9373986

    AN - SCOPUS:0030662183

    VL - 102

    SP - 2993

    EP - 2996

    JO - Journal of the Acoustical Society of America

    JF - Journal of the Acoustical Society of America

    SN - 0001-4966

    IS - 5 I

    ER -