Predicted efficiency of a Low-temperature Nanofluid-based direct absorption solar collector

Himanshu Tyagi, Patrick Phelan, Ravi Prasher

Research output: Contribution to journalArticle

358 Citations (Scopus)

Abstract

Due to its renewable and nonpolluting nature, solar energy is often used in applications such as electricity generation, thermal heating, and chemical processing. The most costeffective solar heaters are of the "flat- plate" type, but these suffer from relatively low efficiency and outlet temperatures. The present study theoretically investigates the feasibility of using a nonconcentrating direct absorption solar collector (DAC) and compares its performance with that of a typical flat-plate collector. Here a nanofluid-a mixture of water and aluminum nanoparticles-is used as the absorbing medium. A two-dimensional heat transfer analysis was developed in which direct sunlight was incident on a thin flowing film of nanofluid. The effects of absorption and scattering within the nanofluid were accounted for. In order to evaluate the temperature profile and intensity distribution within the nanofluid, the energy balance equation and heat transport equation were solved numerically. It was observed that the presence of nanoparticles increases the absorption of incident radiation by more than nine times over that of pure water. According to the results obtained from this study, under similar operating conditions, the efficiency of a DAC using nanofluid as the working fluid is found to be up to 10% higher (on an absolute basis) than that of a flat-plate collector. Generally a DAC using nanofluids as the working fluid performs better than a flat-plate collector, however, much better designed flat-plate collectors might be able to match or outperform a nanofluids based DAC under certain conditions.

Original languageEnglish (US)
Pages (from-to)410041-410047
Number of pages7
JournalJournal of Solar Energy Engineering, Transactions of the ASME
Volume131
Issue number4
DOIs
StatePublished - Nov 2009
Externally publishedYes

Fingerprint

Solar collectors
Nanoparticles
Temperature
Fluids
Energy balance
Solar energy
Water
Electricity
Scattering
Heat transfer
Aluminum
Radiation
Heating
Processing
Hot Temperature

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Renewable Energy, Sustainability and the Environment

Cite this

Predicted efficiency of a Low-temperature Nanofluid-based direct absorption solar collector. / Tyagi, Himanshu; Phelan, Patrick; Prasher, Ravi.

In: Journal of Solar Energy Engineering, Transactions of the ASME, Vol. 131, No. 4, 11.2009, p. 410041-410047.

Research output: Contribution to journalArticle

@article{1d43e2bdcfd84b0186fdadd9c44a4c5b,
title = "Predicted efficiency of a Low-temperature Nanofluid-based direct absorption solar collector",
abstract = "Due to its renewable and nonpolluting nature, solar energy is often used in applications such as electricity generation, thermal heating, and chemical processing. The most costeffective solar heaters are of the {"}flat- plate{"} type, but these suffer from relatively low efficiency and outlet temperatures. The present study theoretically investigates the feasibility of using a nonconcentrating direct absorption solar collector (DAC) and compares its performance with that of a typical flat-plate collector. Here a nanofluid-a mixture of water and aluminum nanoparticles-is used as the absorbing medium. A two-dimensional heat transfer analysis was developed in which direct sunlight was incident on a thin flowing film of nanofluid. The effects of absorption and scattering within the nanofluid were accounted for. In order to evaluate the temperature profile and intensity distribution within the nanofluid, the energy balance equation and heat transport equation were solved numerically. It was observed that the presence of nanoparticles increases the absorption of incident radiation by more than nine times over that of pure water. According to the results obtained from this study, under similar operating conditions, the efficiency of a DAC using nanofluid as the working fluid is found to be up to 10{\%} higher (on an absolute basis) than that of a flat-plate collector. Generally a DAC using nanofluids as the working fluid performs better than a flat-plate collector, however, much better designed flat-plate collectors might be able to match or outperform a nanofluids based DAC under certain conditions.",
author = "Himanshu Tyagi and Patrick Phelan and Ravi Prasher",
year = "2009",
month = "11",
doi = "10.1115/1.3197562",
language = "English (US)",
volume = "131",
pages = "410041--410047",
journal = "Journal of Solar Energy Engineering, Transactions of the ASME",
issn = "0199-6231",
publisher = "American Society of Mechanical Engineers(ASME)",
number = "4",

}

TY - JOUR

T1 - Predicted efficiency of a Low-temperature Nanofluid-based direct absorption solar collector

AU - Tyagi, Himanshu

AU - Phelan, Patrick

AU - Prasher, Ravi

PY - 2009/11

Y1 - 2009/11

N2 - Due to its renewable and nonpolluting nature, solar energy is often used in applications such as electricity generation, thermal heating, and chemical processing. The most costeffective solar heaters are of the "flat- plate" type, but these suffer from relatively low efficiency and outlet temperatures. The present study theoretically investigates the feasibility of using a nonconcentrating direct absorption solar collector (DAC) and compares its performance with that of a typical flat-plate collector. Here a nanofluid-a mixture of water and aluminum nanoparticles-is used as the absorbing medium. A two-dimensional heat transfer analysis was developed in which direct sunlight was incident on a thin flowing film of nanofluid. The effects of absorption and scattering within the nanofluid were accounted for. In order to evaluate the temperature profile and intensity distribution within the nanofluid, the energy balance equation and heat transport equation were solved numerically. It was observed that the presence of nanoparticles increases the absorption of incident radiation by more than nine times over that of pure water. According to the results obtained from this study, under similar operating conditions, the efficiency of a DAC using nanofluid as the working fluid is found to be up to 10% higher (on an absolute basis) than that of a flat-plate collector. Generally a DAC using nanofluids as the working fluid performs better than a flat-plate collector, however, much better designed flat-plate collectors might be able to match or outperform a nanofluids based DAC under certain conditions.

AB - Due to its renewable and nonpolluting nature, solar energy is often used in applications such as electricity generation, thermal heating, and chemical processing. The most costeffective solar heaters are of the "flat- plate" type, but these suffer from relatively low efficiency and outlet temperatures. The present study theoretically investigates the feasibility of using a nonconcentrating direct absorption solar collector (DAC) and compares its performance with that of a typical flat-plate collector. Here a nanofluid-a mixture of water and aluminum nanoparticles-is used as the absorbing medium. A two-dimensional heat transfer analysis was developed in which direct sunlight was incident on a thin flowing film of nanofluid. The effects of absorption and scattering within the nanofluid were accounted for. In order to evaluate the temperature profile and intensity distribution within the nanofluid, the energy balance equation and heat transport equation were solved numerically. It was observed that the presence of nanoparticles increases the absorption of incident radiation by more than nine times over that of pure water. According to the results obtained from this study, under similar operating conditions, the efficiency of a DAC using nanofluid as the working fluid is found to be up to 10% higher (on an absolute basis) than that of a flat-plate collector. Generally a DAC using nanofluids as the working fluid performs better than a flat-plate collector, however, much better designed flat-plate collectors might be able to match or outperform a nanofluids based DAC under certain conditions.

UR - http://www.scopus.com/inward/record.url?scp=77955180865&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77955180865&partnerID=8YFLogxK

U2 - 10.1115/1.3197562

DO - 10.1115/1.3197562

M3 - Article

VL - 131

SP - 410041

EP - 410047

JO - Journal of Solar Energy Engineering, Transactions of the ASME

JF - Journal of Solar Energy Engineering, Transactions of the ASME

SN - 0199-6231

IS - 4

ER -