Postconstruction evaluation of horizontal directional drilling installations

Samuel Ariaratnam, Ivan J. Beljan

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

Recently, questions have arisen concerning the compactive nature of drilling fluids within the annular space during horizontal directional drilling (HDD) operations. To address these concerns, a field and laboratory study was conducted to provide both a qualitative and a quantitative assessment of the annular space. The study consisted of installing 61 m (200 ft) bore lengths of 100 mm (4 in.), 200 mm (8 in.), and 300 mm (12 in.) SDR 17 high density polyethylene pipe in two different soil mediums: clay and sand. Subsequently, the pipes were excavated with visual and strength measures of each of the installations taken at time periods of 1 day, 1 week, 2 weeks, 4 weeks, and 1 year after installation to assess the annular space region over time. Additionally, samples of the drilling fluid were evaluated both in the field and at a laboratory. This paper presents the results of this research initiative and provides qualitative and quantitative information on borehole annular space integrity during HDD installations. The study revealed that: (1) the integrity of the annular space was maintained, as little evidence of voids was present; and (2) the strength properties increased over time through apparent consolidation, or equalization, with the native soil.

Original languageEnglish (US)
Pages (from-to)115-126
Number of pages12
JournalPractice Periodical on Structural Design and Construction
Volume10
Issue number2
DOIs
StatePublished - May 2005

Fingerprint

Directional drilling
Horizontal drilling
Drilling fluids
Pipe
Soils
High density polyethylenes
Boreholes
Consolidation
Clay
Sand
Evaluation

Keywords

  • Drilling
  • Performance evaluation
  • Pipelines
  • Trenchless technology
  • Underground construction

ASJC Scopus subject areas

  • Architecture

Cite this

Postconstruction evaluation of horizontal directional drilling installations. / Ariaratnam, Samuel; Beljan, Ivan J.

In: Practice Periodical on Structural Design and Construction, Vol. 10, No. 2, 05.2005, p. 115-126.

Research output: Contribution to journalArticle

@article{9bdde7954571420dbebae90ce7b900c6,
title = "Postconstruction evaluation of horizontal directional drilling installations",
abstract = "Recently, questions have arisen concerning the compactive nature of drilling fluids within the annular space during horizontal directional drilling (HDD) operations. To address these concerns, a field and laboratory study was conducted to provide both a qualitative and a quantitative assessment of the annular space. The study consisted of installing 61 m (200 ft) bore lengths of 100 mm (4 in.), 200 mm (8 in.), and 300 mm (12 in.) SDR 17 high density polyethylene pipe in two different soil mediums: clay and sand. Subsequently, the pipes were excavated with visual and strength measures of each of the installations taken at time periods of 1 day, 1 week, 2 weeks, 4 weeks, and 1 year after installation to assess the annular space region over time. Additionally, samples of the drilling fluid were evaluated both in the field and at a laboratory. This paper presents the results of this research initiative and provides qualitative and quantitative information on borehole annular space integrity during HDD installations. The study revealed that: (1) the integrity of the annular space was maintained, as little evidence of voids was present; and (2) the strength properties increased over time through apparent consolidation, or equalization, with the native soil.",
keywords = "Drilling, Performance evaluation, Pipelines, Trenchless technology, Underground construction",
author = "Samuel Ariaratnam and Beljan, {Ivan J.}",
year = "2005",
month = "5",
doi = "10.1061/(ASCE)1084-0680(2005)10:2(115)",
language = "English (US)",
volume = "10",
pages = "115--126",
journal = "Practice Periodical on Structural Design and Construction",
issn = "1084-0680",
publisher = "American Society of Civil Engineers (ASCE)",
number = "2",

}

TY - JOUR

T1 - Postconstruction evaluation of horizontal directional drilling installations

AU - Ariaratnam, Samuel

AU - Beljan, Ivan J.

PY - 2005/5

Y1 - 2005/5

N2 - Recently, questions have arisen concerning the compactive nature of drilling fluids within the annular space during horizontal directional drilling (HDD) operations. To address these concerns, a field and laboratory study was conducted to provide both a qualitative and a quantitative assessment of the annular space. The study consisted of installing 61 m (200 ft) bore lengths of 100 mm (4 in.), 200 mm (8 in.), and 300 mm (12 in.) SDR 17 high density polyethylene pipe in two different soil mediums: clay and sand. Subsequently, the pipes were excavated with visual and strength measures of each of the installations taken at time periods of 1 day, 1 week, 2 weeks, 4 weeks, and 1 year after installation to assess the annular space region over time. Additionally, samples of the drilling fluid were evaluated both in the field and at a laboratory. This paper presents the results of this research initiative and provides qualitative and quantitative information on borehole annular space integrity during HDD installations. The study revealed that: (1) the integrity of the annular space was maintained, as little evidence of voids was present; and (2) the strength properties increased over time through apparent consolidation, or equalization, with the native soil.

AB - Recently, questions have arisen concerning the compactive nature of drilling fluids within the annular space during horizontal directional drilling (HDD) operations. To address these concerns, a field and laboratory study was conducted to provide both a qualitative and a quantitative assessment of the annular space. The study consisted of installing 61 m (200 ft) bore lengths of 100 mm (4 in.), 200 mm (8 in.), and 300 mm (12 in.) SDR 17 high density polyethylene pipe in two different soil mediums: clay and sand. Subsequently, the pipes were excavated with visual and strength measures of each of the installations taken at time periods of 1 day, 1 week, 2 weeks, 4 weeks, and 1 year after installation to assess the annular space region over time. Additionally, samples of the drilling fluid were evaluated both in the field and at a laboratory. This paper presents the results of this research initiative and provides qualitative and quantitative information on borehole annular space integrity during HDD installations. The study revealed that: (1) the integrity of the annular space was maintained, as little evidence of voids was present; and (2) the strength properties increased over time through apparent consolidation, or equalization, with the native soil.

KW - Drilling

KW - Performance evaluation

KW - Pipelines

KW - Trenchless technology

KW - Underground construction

UR - http://www.scopus.com/inward/record.url?scp=18444384544&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=18444384544&partnerID=8YFLogxK

U2 - 10.1061/(ASCE)1084-0680(2005)10:2(115)

DO - 10.1061/(ASCE)1084-0680(2005)10:2(115)

M3 - Article

AN - SCOPUS:18444384544

VL - 10

SP - 115

EP - 126

JO - Practice Periodical on Structural Design and Construction

JF - Practice Periodical on Structural Design and Construction

SN - 1084-0680

IS - 2

ER -