Optically seamless flexible electronic tiles for ultra large-area digital X-ray imaging

Joseph T. Smith, Aaron J. Couture, John R. Stowell, David Allee

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

This paper presents a new flexible electronics assembly technique that combines individual digital X-ray detectors to create a much larger composite digital X-ray detector. The new assembly technique uses multiple flexible digital X-ray detectors manufactured on a thin, transparent, and flexible plastic substrate, which are overlapped to create the larger composite X-ray detector. The assembly technique, illustrated in a mechanical mockup, is optically seamless, and has the ability to scale up to extremely large X-ray imaging arrays. Feasibility and preliminary imaging performance were demonstrated by tiling several 16 × 16 pixel resolution prototype flexible X-ray detector test structures. Optical losses under typical digital radiography conditions were also measured by overlapping a plastic substrate flexible X-ray detector onto a commercial glass substrate digital X-ray imaging array. Approximately 5% signal loss was observed in the transparent plastic overlap region, and the seam edge imaging artifact was demonstrated to be correctable using commercial gain calibration. A key medical imaging application for this technology is single-exposure, low-dose, and full-body digital radiography.

Original languageEnglish (US)
Article number6809150
Pages (from-to)1109-1115
Number of pages7
JournalIEEE Transactions on Components, Packaging and Manufacturing Technology
Volume4
Issue number6
DOIs
StatePublished - 2014

Fingerprint

Flexible electronics
Tile
Imaging techniques
X rays
Detectors
Radiography
Plastics
Substrates
Optical losses
Optical resolving power
Medical imaging
Composite materials
Pixels
Calibration
Glass

Keywords

  • Digital X-ray
  • flexible electronics
  • indium-gallium-zinc oxide (IGZO)
  • thin-film transistors (TFTs)
  • tiling.

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Electronic, Optical and Magnetic Materials
  • Industrial and Manufacturing Engineering

Cite this

Optically seamless flexible electronic tiles for ultra large-area digital X-ray imaging. / Smith, Joseph T.; Couture, Aaron J.; Stowell, John R.; Allee, David.

In: IEEE Transactions on Components, Packaging and Manufacturing Technology, Vol. 4, No. 6, 6809150, 2014, p. 1109-1115.

Research output: Contribution to journalArticle

@article{ac2aa857b6c0498f8516275c098fc8fc,
title = "Optically seamless flexible electronic tiles for ultra large-area digital X-ray imaging",
abstract = "This paper presents a new flexible electronics assembly technique that combines individual digital X-ray detectors to create a much larger composite digital X-ray detector. The new assembly technique uses multiple flexible digital X-ray detectors manufactured on a thin, transparent, and flexible plastic substrate, which are overlapped to create the larger composite X-ray detector. The assembly technique, illustrated in a mechanical mockup, is optically seamless, and has the ability to scale up to extremely large X-ray imaging arrays. Feasibility and preliminary imaging performance were demonstrated by tiling several 16 × 16 pixel resolution prototype flexible X-ray detector test structures. Optical losses under typical digital radiography conditions were also measured by overlapping a plastic substrate flexible X-ray detector onto a commercial glass substrate digital X-ray imaging array. Approximately 5{\%} signal loss was observed in the transparent plastic overlap region, and the seam edge imaging artifact was demonstrated to be correctable using commercial gain calibration. A key medical imaging application for this technology is single-exposure, low-dose, and full-body digital radiography.",
keywords = "Digital X-ray, flexible electronics, indium-gallium-zinc oxide (IGZO), thin-film transistors (TFTs), tiling.",
author = "Smith, {Joseph T.} and Couture, {Aaron J.} and Stowell, {John R.} and David Allee",
year = "2014",
doi = "10.1109/TCPMT.2014.2316477",
language = "English (US)",
volume = "4",
pages = "1109--1115",
journal = "IEEE Transactions on Components, Packaging and Manufacturing Technology",
issn = "2156-3950",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "6",

}

TY - JOUR

T1 - Optically seamless flexible electronic tiles for ultra large-area digital X-ray imaging

AU - Smith, Joseph T.

AU - Couture, Aaron J.

AU - Stowell, John R.

AU - Allee, David

PY - 2014

Y1 - 2014

N2 - This paper presents a new flexible electronics assembly technique that combines individual digital X-ray detectors to create a much larger composite digital X-ray detector. The new assembly technique uses multiple flexible digital X-ray detectors manufactured on a thin, transparent, and flexible plastic substrate, which are overlapped to create the larger composite X-ray detector. The assembly technique, illustrated in a mechanical mockup, is optically seamless, and has the ability to scale up to extremely large X-ray imaging arrays. Feasibility and preliminary imaging performance were demonstrated by tiling several 16 × 16 pixel resolution prototype flexible X-ray detector test structures. Optical losses under typical digital radiography conditions were also measured by overlapping a plastic substrate flexible X-ray detector onto a commercial glass substrate digital X-ray imaging array. Approximately 5% signal loss was observed in the transparent plastic overlap region, and the seam edge imaging artifact was demonstrated to be correctable using commercial gain calibration. A key medical imaging application for this technology is single-exposure, low-dose, and full-body digital radiography.

AB - This paper presents a new flexible electronics assembly technique that combines individual digital X-ray detectors to create a much larger composite digital X-ray detector. The new assembly technique uses multiple flexible digital X-ray detectors manufactured on a thin, transparent, and flexible plastic substrate, which are overlapped to create the larger composite X-ray detector. The assembly technique, illustrated in a mechanical mockup, is optically seamless, and has the ability to scale up to extremely large X-ray imaging arrays. Feasibility and preliminary imaging performance were demonstrated by tiling several 16 × 16 pixel resolution prototype flexible X-ray detector test structures. Optical losses under typical digital radiography conditions were also measured by overlapping a plastic substrate flexible X-ray detector onto a commercial glass substrate digital X-ray imaging array. Approximately 5% signal loss was observed in the transparent plastic overlap region, and the seam edge imaging artifact was demonstrated to be correctable using commercial gain calibration. A key medical imaging application for this technology is single-exposure, low-dose, and full-body digital radiography.

KW - Digital X-ray

KW - flexible electronics

KW - indium-gallium-zinc oxide (IGZO)

KW - thin-film transistors (TFTs)

KW - tiling.

UR - http://www.scopus.com/inward/record.url?scp=84902193807&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84902193807&partnerID=8YFLogxK

U2 - 10.1109/TCPMT.2014.2316477

DO - 10.1109/TCPMT.2014.2316477

M3 - Article

AN - SCOPUS:84902193807

VL - 4

SP - 1109

EP - 1115

JO - IEEE Transactions on Components, Packaging and Manufacturing Technology

JF - IEEE Transactions on Components, Packaging and Manufacturing Technology

SN - 2156-3950

IS - 6

M1 - 6809150

ER -