Conventional approaches of implementing computational fluid dynamics to study aneurysmal hemodynamics after treatment with a flow diverter stent are computationally expensive. Cumbersome meshing and lengthy simulation runtimes are common. To address these issues, we present a novel volume penalization method that considers flow diverters as heterogeneous porous media. The proposed model requires a considerably smaller number of mesh elements, leading to faster simulation runtimes. Three patient-specific aneurysms were virtually treated with flow diverters and aneurysmal hemodynamics were simulated. The results of the virtual deployments including aneurysmal hemodynamics were compared to corresponding results from conventional approaches. The comparisons showed that the proposed approach led to 9.12 times increase in the speed of simulations on average. Further, aneurysmal kinetic energy and inflow rate metrics for the proposed approach were consistent with those from conventional approaches, differing on average by 3.52% and 3.78%, respectively.

Fingerprint

Stents
Hemodynamics
Porous materials
Brain
Kinetic energy
Computational fluid dynamics

Keywords

  • Brain aneurysm
  • CFD
  • flow diverter
  • hemodynamic
  • porous medium

ASJC Scopus subject areas

  • Bioengineering
  • Biomedical Engineering
  • Human-Computer Interaction
  • Computer Science Applications

Cite this

Numerical study of hemodynamics in brain aneurysms treated with flow diverter stents using porous medium theory. / Yadollahi-Farsani, Hooman; Scougal, Erik; Herrmann, Marcus; Wei, Wei; Frakes, David; Chong, Brian.

In: Computer Methods in Biomechanics and Biomedical Engineering, 01.01.2019.

Research output: Contribution to journalArticle

@article{d23611f0f2bc48beafed115b366aa7f6,
title = "Numerical study of hemodynamics in brain aneurysms treated with flow diverter stents using porous medium theory",
abstract = "Conventional approaches of implementing computational fluid dynamics to study aneurysmal hemodynamics after treatment with a flow diverter stent are computationally expensive. Cumbersome meshing and lengthy simulation runtimes are common. To address these issues, we present a novel volume penalization method that considers flow diverters as heterogeneous porous media. The proposed model requires a considerably smaller number of mesh elements, leading to faster simulation runtimes. Three patient-specific aneurysms were virtually treated with flow diverters and aneurysmal hemodynamics were simulated. The results of the virtual deployments including aneurysmal hemodynamics were compared to corresponding results from conventional approaches. The comparisons showed that the proposed approach led to 9.12 times increase in the speed of simulations on average. Further, aneurysmal kinetic energy and inflow rate metrics for the proposed approach were consistent with those from conventional approaches, differing on average by 3.52{\%} and 3.78{\%}, respectively.",
keywords = "Brain aneurysm, CFD, flow diverter, hemodynamic, porous medium",
author = "Hooman Yadollahi-Farsani and Erik Scougal and Marcus Herrmann and Wei Wei and David Frakes and Brian Chong",
year = "2019",
month = "1",
day = "1",
doi = "10.1080/10255842.2019.1609457",
language = "English (US)",
journal = "Computer Methods in Biomechanics and Biomedical Engineering",
issn = "1025-5842",
publisher = "Informa Healthcare",

}

TY - JOUR

T1 - Numerical study of hemodynamics in brain aneurysms treated with flow diverter stents using porous medium theory

AU - Yadollahi-Farsani, Hooman

AU - Scougal, Erik

AU - Herrmann, Marcus

AU - Wei, Wei

AU - Frakes, David

AU - Chong, Brian

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Conventional approaches of implementing computational fluid dynamics to study aneurysmal hemodynamics after treatment with a flow diverter stent are computationally expensive. Cumbersome meshing and lengthy simulation runtimes are common. To address these issues, we present a novel volume penalization method that considers flow diverters as heterogeneous porous media. The proposed model requires a considerably smaller number of mesh elements, leading to faster simulation runtimes. Three patient-specific aneurysms were virtually treated with flow diverters and aneurysmal hemodynamics were simulated. The results of the virtual deployments including aneurysmal hemodynamics were compared to corresponding results from conventional approaches. The comparisons showed that the proposed approach led to 9.12 times increase in the speed of simulations on average. Further, aneurysmal kinetic energy and inflow rate metrics for the proposed approach were consistent with those from conventional approaches, differing on average by 3.52% and 3.78%, respectively.

AB - Conventional approaches of implementing computational fluid dynamics to study aneurysmal hemodynamics after treatment with a flow diverter stent are computationally expensive. Cumbersome meshing and lengthy simulation runtimes are common. To address these issues, we present a novel volume penalization method that considers flow diverters as heterogeneous porous media. The proposed model requires a considerably smaller number of mesh elements, leading to faster simulation runtimes. Three patient-specific aneurysms were virtually treated with flow diverters and aneurysmal hemodynamics were simulated. The results of the virtual deployments including aneurysmal hemodynamics were compared to corresponding results from conventional approaches. The comparisons showed that the proposed approach led to 9.12 times increase in the speed of simulations on average. Further, aneurysmal kinetic energy and inflow rate metrics for the proposed approach were consistent with those from conventional approaches, differing on average by 3.52% and 3.78%, respectively.

KW - Brain aneurysm

KW - CFD

KW - flow diverter

KW - hemodynamic

KW - porous medium

UR - http://www.scopus.com/inward/record.url?scp=85065330005&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85065330005&partnerID=8YFLogxK

U2 - 10.1080/10255842.2019.1609457

DO - 10.1080/10255842.2019.1609457

M3 - Article

JO - Computer Methods in Biomechanics and Biomedical Engineering

JF - Computer Methods in Biomechanics and Biomedical Engineering

SN - 1025-5842

ER -