X-ray free-electron lasers overcome the problem of radiation damage in protein crystallography and allow structure determination from micro- and nanocrystals at room temperature. To ensure that consecutive X-ray pulses do not probe previously exposed crystals, the sample needs to be replaced with the X-ray repetition rate, which ranges from 120 Hz at warm linacbased free-electron lasers to 1 MHz at superconducting linacs. Liquid injectors are therefore an essential part of a serial femtosecond crystallography experiment at an X-ray free-electron laser. Here, we compare different techniques of injecting microcrystals in solution into the pulsed X-ray beam in vacuum. Sample waste due to mismatch of the liquid flow rate to the X-ray repetition rate can be addressed through various techniques.

Original languageEnglish (US)
Article number20130337
JournalPhilosophical Transactions of the Royal Society B: Biological Sciences
Volume369
Issue number1647
DOIs
StatePublished - Jul 17 2014

Fingerprint

crystallography
Crystallography
Free electron lasers
X-radiation
X-Rays
X ray lasers
X rays
Microcrystals
liquid
liquids
Liquids
lasers
Lasers
laser
electrons
Electrons
sampling
electron
Radiation damage
methodology

Keywords

  • Crystallography
  • Liquid jets
  • Serial femtosecond
  • X-ray free-electron laser

ASJC Scopus subject areas

  • Agricultural and Biological Sciences(all)
  • Biochemistry, Genetics and Molecular Biology(all)
  • Medicine(all)

Cite this

@article{9a1ab82654d145da897048ef75a22c7d,
title = "Liquid sample delivery techniques for serial femtosecond crystallography",
abstract = "X-ray free-electron lasers overcome the problem of radiation damage in protein crystallography and allow structure determination from micro- and nanocrystals at room temperature. To ensure that consecutive X-ray pulses do not probe previously exposed crystals, the sample needs to be replaced with the X-ray repetition rate, which ranges from 120 Hz at warm linacbased free-electron lasers to 1 MHz at superconducting linacs. Liquid injectors are therefore an essential part of a serial femtosecond crystallography experiment at an X-ray free-electron laser. Here, we compare different techniques of injecting microcrystals in solution into the pulsed X-ray beam in vacuum. Sample waste due to mismatch of the liquid flow rate to the X-ray repetition rate can be addressed through various techniques.",
keywords = "Crystallography, Liquid jets, Serial femtosecond, X-ray free-electron laser",
author = "Uwe Weierstall",
year = "2014",
month = "7",
day = "17",
doi = "10.1098/rstb.2013.0337",
language = "English (US)",
volume = "369",
journal = "Philosophical Transactions of the Royal Society B: Biological Sciences",
issn = "0800-4622",
publisher = "Royal Society of London",
number = "1647",

}

TY - JOUR

T1 - Liquid sample delivery techniques for serial femtosecond crystallography

AU - Weierstall, Uwe

PY - 2014/7/17

Y1 - 2014/7/17

N2 - X-ray free-electron lasers overcome the problem of radiation damage in protein crystallography and allow structure determination from micro- and nanocrystals at room temperature. To ensure that consecutive X-ray pulses do not probe previously exposed crystals, the sample needs to be replaced with the X-ray repetition rate, which ranges from 120 Hz at warm linacbased free-electron lasers to 1 MHz at superconducting linacs. Liquid injectors are therefore an essential part of a serial femtosecond crystallography experiment at an X-ray free-electron laser. Here, we compare different techniques of injecting microcrystals in solution into the pulsed X-ray beam in vacuum. Sample waste due to mismatch of the liquid flow rate to the X-ray repetition rate can be addressed through various techniques.

AB - X-ray free-electron lasers overcome the problem of radiation damage in protein crystallography and allow structure determination from micro- and nanocrystals at room temperature. To ensure that consecutive X-ray pulses do not probe previously exposed crystals, the sample needs to be replaced with the X-ray repetition rate, which ranges from 120 Hz at warm linacbased free-electron lasers to 1 MHz at superconducting linacs. Liquid injectors are therefore an essential part of a serial femtosecond crystallography experiment at an X-ray free-electron laser. Here, we compare different techniques of injecting microcrystals in solution into the pulsed X-ray beam in vacuum. Sample waste due to mismatch of the liquid flow rate to the X-ray repetition rate can be addressed through various techniques.

KW - Crystallography

KW - Liquid jets

KW - Serial femtosecond

KW - X-ray free-electron laser

UR - http://www.scopus.com/inward/record.url?scp=84902668642&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84902668642&partnerID=8YFLogxK

U2 - 10.1098/rstb.2013.0337

DO - 10.1098/rstb.2013.0337

M3 - Article

C2 - 24914163

AN - SCOPUS:84902668642

VL - 369

JO - Philosophical Transactions of the Royal Society B: Biological Sciences

JF - Philosophical Transactions of the Royal Society B: Biological Sciences

SN - 0800-4622

IS - 1647

M1 - 20130337

ER -