High-speed on-demand 3D printed bioresorbable vascular scaffolds

Henry Oliver T. Ware, Adam C. Farsheed, Banu Akar, Chongwen Duan, Xiangfan Chen, Guillermo Ameer, Cheng Sun

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Recent development of the high-resolution Micro-Continuous Liquid Interface Production (μCLIP) process has enabled 3D printing of biomedical devices with micron-scale precision. Despite our recent success in demonstrating fabrication of bioresorbable vascular scaffolds (BVS) via μCLIP, key technical obstacles remain. Specifically, achieving comparable radial stiffness to nitinol stents required strut thickness of 400 μm. Such large struts would negatively affect blood flow through smaller coronary vessels. Low printing speed also made the process impractical for potential on-demand fabrication of patient-specific BVSs. Lack of a systematic optimization strategy capturing the sophisticated process-materials-performance dependencies impedes development of on-demand fabrication of BVSs and other biomedical devices. Herein, we developed a systematic method to optimize the entangled process parameters, such as materials strength/stiffness, exposure dosage, and fabrication speed. A dedicated speed working curve method was developed to calibrate the μCLIP process, which allowed experimental determination of dimensionally-accurate fabrication parameters. Composition of the citric acid-based bioresorbable ink (B-Ink™) was optimized to maximize BVS radial stiffness, allowing scaffold struts at clinically-relevant sizes. Through the described dual optimization, we have successfully fabricated BVSs with radial stiffness comparable to nitinol stents and strut thickness of 150 μm, which is comparable to the ABSORB GT1BVS. Fabrication of 2-cm long BVS with 5 μm, 10 μm, and 15 μm layer slicing can now be accomplished within 26.5, 15.3, and 11.3 min, respectively. The reported process optimization methods and high-speed, high-resolution 3D printing capability demonstrate a promising solution for on-demand fabrication of patient-specific biomedical devices.

Original languageEnglish (US)
Pages (from-to)25-34
Number of pages10
JournalMaterials Today Chemistry
Volume7
DOIs
StatePublished - Mar 2018
Externally publishedYes

Fingerprint

Scaffolds
Struts
Fabrication
Stiffness
Printing
Stents
Liquids
Citric acid
Ink
Citric Acid
Blood
Chemical analysis

Keywords

  • 3D printing
  • Bioresorbable vascular scaffold
  • Micro-continuous liquid interface production (μCLIP)

ASJC Scopus subject areas

  • Catalysis
  • Electronic, Optical and Magnetic Materials
  • Biomaterials
  • Polymers and Plastics
  • Colloid and Surface Chemistry
  • Materials Chemistry

Cite this

Ware, H. O. T., Farsheed, A. C., Akar, B., Duan, C., Chen, X., Ameer, G., & Sun, C. (2018). High-speed on-demand 3D printed bioresorbable vascular scaffolds. Materials Today Chemistry, 7, 25-34. https://doi.org/10.1016/j.mtchem.2017.10.002

High-speed on-demand 3D printed bioresorbable vascular scaffolds. / Ware, Henry Oliver T.; Farsheed, Adam C.; Akar, Banu; Duan, Chongwen; Chen, Xiangfan; Ameer, Guillermo; Sun, Cheng.

In: Materials Today Chemistry, Vol. 7, 03.2018, p. 25-34.

Research output: Contribution to journalArticle

Ware, Henry Oliver T. ; Farsheed, Adam C. ; Akar, Banu ; Duan, Chongwen ; Chen, Xiangfan ; Ameer, Guillermo ; Sun, Cheng. / High-speed on-demand 3D printed bioresorbable vascular scaffolds. In: Materials Today Chemistry. 2018 ; Vol. 7. pp. 25-34.
@article{5b5080e42f9344a5ade2469d08b146d1,
title = "High-speed on-demand 3D printed bioresorbable vascular scaffolds",
abstract = "Recent development of the high-resolution Micro-Continuous Liquid Interface Production (μCLIP) process has enabled 3D printing of biomedical devices with micron-scale precision. Despite our recent success in demonstrating fabrication of bioresorbable vascular scaffolds (BVS) via μCLIP, key technical obstacles remain. Specifically, achieving comparable radial stiffness to nitinol stents required strut thickness of 400 μm. Such large struts would negatively affect blood flow through smaller coronary vessels. Low printing speed also made the process impractical for potential on-demand fabrication of patient-specific BVSs. Lack of a systematic optimization strategy capturing the sophisticated process-materials-performance dependencies impedes development of on-demand fabrication of BVSs and other biomedical devices. Herein, we developed a systematic method to optimize the entangled process parameters, such as materials strength/stiffness, exposure dosage, and fabrication speed. A dedicated speed working curve method was developed to calibrate the μCLIP process, which allowed experimental determination of dimensionally-accurate fabrication parameters. Composition of the citric acid-based bioresorbable ink (B-Ink™) was optimized to maximize BVS radial stiffness, allowing scaffold struts at clinically-relevant sizes. Through the described dual optimization, we have successfully fabricated BVSs with radial stiffness comparable to nitinol stents and strut thickness of 150 μm, which is comparable to the ABSORB GT1BVS. Fabrication of 2-cm long BVS with 5 μm, 10 μm, and 15 μm layer slicing can now be accomplished within 26.5, 15.3, and 11.3 min, respectively. The reported process optimization methods and high-speed, high-resolution 3D printing capability demonstrate a promising solution for on-demand fabrication of patient-specific biomedical devices.",
keywords = "3D printing, Bioresorbable vascular scaffold, Micro-continuous liquid interface production (μCLIP)",
author = "Ware, {Henry Oliver T.} and Farsheed, {Adam C.} and Banu Akar and Chongwen Duan and Xiangfan Chen and Guillermo Ameer and Cheng Sun",
year = "2018",
month = "3",
doi = "10.1016/j.mtchem.2017.10.002",
language = "English (US)",
volume = "7",
pages = "25--34",
journal = "Materials Today Chemistry",
issn = "2468-5194",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - High-speed on-demand 3D printed bioresorbable vascular scaffolds

AU - Ware, Henry Oliver T.

AU - Farsheed, Adam C.

AU - Akar, Banu

AU - Duan, Chongwen

AU - Chen, Xiangfan

AU - Ameer, Guillermo

AU - Sun, Cheng

PY - 2018/3

Y1 - 2018/3

N2 - Recent development of the high-resolution Micro-Continuous Liquid Interface Production (μCLIP) process has enabled 3D printing of biomedical devices with micron-scale precision. Despite our recent success in demonstrating fabrication of bioresorbable vascular scaffolds (BVS) via μCLIP, key technical obstacles remain. Specifically, achieving comparable radial stiffness to nitinol stents required strut thickness of 400 μm. Such large struts would negatively affect blood flow through smaller coronary vessels. Low printing speed also made the process impractical for potential on-demand fabrication of patient-specific BVSs. Lack of a systematic optimization strategy capturing the sophisticated process-materials-performance dependencies impedes development of on-demand fabrication of BVSs and other biomedical devices. Herein, we developed a systematic method to optimize the entangled process parameters, such as materials strength/stiffness, exposure dosage, and fabrication speed. A dedicated speed working curve method was developed to calibrate the μCLIP process, which allowed experimental determination of dimensionally-accurate fabrication parameters. Composition of the citric acid-based bioresorbable ink (B-Ink™) was optimized to maximize BVS radial stiffness, allowing scaffold struts at clinically-relevant sizes. Through the described dual optimization, we have successfully fabricated BVSs with radial stiffness comparable to nitinol stents and strut thickness of 150 μm, which is comparable to the ABSORB GT1BVS. Fabrication of 2-cm long BVS with 5 μm, 10 μm, and 15 μm layer slicing can now be accomplished within 26.5, 15.3, and 11.3 min, respectively. The reported process optimization methods and high-speed, high-resolution 3D printing capability demonstrate a promising solution for on-demand fabrication of patient-specific biomedical devices.

AB - Recent development of the high-resolution Micro-Continuous Liquid Interface Production (μCLIP) process has enabled 3D printing of biomedical devices with micron-scale precision. Despite our recent success in demonstrating fabrication of bioresorbable vascular scaffolds (BVS) via μCLIP, key technical obstacles remain. Specifically, achieving comparable radial stiffness to nitinol stents required strut thickness of 400 μm. Such large struts would negatively affect blood flow through smaller coronary vessels. Low printing speed also made the process impractical for potential on-demand fabrication of patient-specific BVSs. Lack of a systematic optimization strategy capturing the sophisticated process-materials-performance dependencies impedes development of on-demand fabrication of BVSs and other biomedical devices. Herein, we developed a systematic method to optimize the entangled process parameters, such as materials strength/stiffness, exposure dosage, and fabrication speed. A dedicated speed working curve method was developed to calibrate the μCLIP process, which allowed experimental determination of dimensionally-accurate fabrication parameters. Composition of the citric acid-based bioresorbable ink (B-Ink™) was optimized to maximize BVS radial stiffness, allowing scaffold struts at clinically-relevant sizes. Through the described dual optimization, we have successfully fabricated BVSs with radial stiffness comparable to nitinol stents and strut thickness of 150 μm, which is comparable to the ABSORB GT1BVS. Fabrication of 2-cm long BVS with 5 μm, 10 μm, and 15 μm layer slicing can now be accomplished within 26.5, 15.3, and 11.3 min, respectively. The reported process optimization methods and high-speed, high-resolution 3D printing capability demonstrate a promising solution for on-demand fabrication of patient-specific biomedical devices.

KW - 3D printing

KW - Bioresorbable vascular scaffold

KW - Micro-continuous liquid interface production (μCLIP)

UR - http://www.scopus.com/inward/record.url?scp=85034614699&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85034614699&partnerID=8YFLogxK

U2 - 10.1016/j.mtchem.2017.10.002

DO - 10.1016/j.mtchem.2017.10.002

M3 - Article

AN - SCOPUS:85034614699

VL - 7

SP - 25

EP - 34

JO - Materials Today Chemistry

JF - Materials Today Chemistry

SN - 2468-5194

ER -