TY - JOUR
T1 - Figures of merit in high-frequency and high-power GaN HEMTs
AU - Marino, F. A.
AU - Faralli, N.
AU - Ferry, D. K.
AU - Goodnick, Stephen
AU - Saraniti, Marco
PY - 2009
Y1 - 2009
N2 - The most important metrics for the high-frequency and high-power performance of microwave transistors are the cut-off frequency fT, and the Johnson figure of merit FoMJohnson. We have simulated a state-of-the-art, high-frequency and high-power GaN HEMT using our full band Cellular Monte Carlo (CMC) simulator, in order to study the RF performance and compare different methods to obtain such metrics. The current gain as a function of the frequency, was so obtained both by the Fourier decomposition (FD) method and the analytical formula proposed by Akis. A cut-off frequency fT of 150 GHz was found in both the transit time analysis given by the analytical approach, and the transient Fourier analysis, which matches well with the 153 GHz value measured experimentally. Furthermore, through some physical considerations, we derived the relation between the FoMJohnson as a function of the breakdown voltage, VBD, and the cut-off frequency, fT . Using this relation and assuming a breakdown voltage of 80V as measured experimentally, a Johnson figure of merit of around 20 × 10 12V/s was found for the HEMT device analyzed in this work.
AB - The most important metrics for the high-frequency and high-power performance of microwave transistors are the cut-off frequency fT, and the Johnson figure of merit FoMJohnson. We have simulated a state-of-the-art, high-frequency and high-power GaN HEMT using our full band Cellular Monte Carlo (CMC) simulator, in order to study the RF performance and compare different methods to obtain such metrics. The current gain as a function of the frequency, was so obtained both by the Fourier decomposition (FD) method and the analytical formula proposed by Akis. A cut-off frequency fT of 150 GHz was found in both the transit time analysis given by the analytical approach, and the transient Fourier analysis, which matches well with the 153 GHz value measured experimentally. Furthermore, through some physical considerations, we derived the relation between the FoMJohnson as a function of the breakdown voltage, VBD, and the cut-off frequency, fT . Using this relation and assuming a breakdown voltage of 80V as measured experimentally, a Johnson figure of merit of around 20 × 10 12V/s was found for the HEMT device analyzed in this work.
UR - http://www.scopus.com/inward/record.url?scp=74549222969&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=74549222969&partnerID=8YFLogxK
U2 - 10.1088/1742-6596/193/1/012040
DO - 10.1088/1742-6596/193/1/012040
M3 - Article
AN - SCOPUS:74549222969
SN - 1742-6588
VL - 193
JO - Journal of Physics: Conference Series
JF - Journal of Physics: Conference Series
M1 - 012040
ER -