EXPERIMENTAL ARC ENERGY METER FOR RELAYS

AK HALDER AK, G KARADY G

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

Meter intended to provide solution to problem of estimating arc energy in contact gaps is described; it also offers possibilities in judging and comparing effectiveness of contact protection devices; through long series of tests, reference charts on suitability of different protection circuits may be compiled by utilizing measured arc energy; for quick and direct appraisal of any new protection circuit only few tests will be ncessary; in field of high voltage circuit breaking, important application of meter could be to measure energy associated with opening of circuit breaker.

Original languageEnglish (US)
Title of host publicationUnknown Host Publication Title
StatePublished - 1969
Externally publishedYes
Event17th Annual Nat Relay Conference, Proc - Stillwater, OK, USA
Duration: Apr 22 1969Apr 23 1969

Other

Other17th Annual Nat Relay Conference, Proc
CityStillwater, OK, USA
Period4/22/694/23/69

Fingerprint

Networks (circuits)
Electric circuit breakers
Electric potential

ASJC Scopus subject areas

  • Engineering(all)

Cite this

HALDER AK, AK., & KARADY G, G. (1969). EXPERIMENTAL ARC ENERGY METER FOR RELAYS. In Unknown Host Publication Title

EXPERIMENTAL ARC ENERGY METER FOR RELAYS. / HALDER AK, AK; KARADY G, G.

Unknown Host Publication Title. 1969.

Research output: Chapter in Book/Report/Conference proceedingChapter

HALDER AK, AK & KARADY G, G 1969, EXPERIMENTAL ARC ENERGY METER FOR RELAYS. in Unknown Host Publication Title. 17th Annual Nat Relay Conference, Proc, Stillwater, OK, USA, 4/22/69.
HALDER AK AK, KARADY G G. EXPERIMENTAL ARC ENERGY METER FOR RELAYS. In Unknown Host Publication Title. 1969
HALDER AK, AK ; KARADY G, G. / EXPERIMENTAL ARC ENERGY METER FOR RELAYS. Unknown Host Publication Title. 1969.
@inbook{1fec088da8794c0d9c6025d149d27576,
title = "EXPERIMENTAL ARC ENERGY METER FOR RELAYS",
abstract = "Meter intended to provide solution to problem of estimating arc energy in contact gaps is described; it also offers possibilities in judging and comparing effectiveness of contact protection devices; through long series of tests, reference charts on suitability of different protection circuits may be compiled by utilizing measured arc energy; for quick and direct appraisal of any new protection circuit only few tests will be ncessary; in field of high voltage circuit breaking, important application of meter could be to measure energy associated with opening of circuit breaker.",
author = "{HALDER AK}, AK and {KARADY G}, G",
year = "1969",
language = "English (US)",
booktitle = "Unknown Host Publication Title",

}

TY - CHAP

T1 - EXPERIMENTAL ARC ENERGY METER FOR RELAYS

AU - HALDER AK, AK

AU - KARADY G, G

PY - 1969

Y1 - 1969

N2 - Meter intended to provide solution to problem of estimating arc energy in contact gaps is described; it also offers possibilities in judging and comparing effectiveness of contact protection devices; through long series of tests, reference charts on suitability of different protection circuits may be compiled by utilizing measured arc energy; for quick and direct appraisal of any new protection circuit only few tests will be ncessary; in field of high voltage circuit breaking, important application of meter could be to measure energy associated with opening of circuit breaker.

AB - Meter intended to provide solution to problem of estimating arc energy in contact gaps is described; it also offers possibilities in judging and comparing effectiveness of contact protection devices; through long series of tests, reference charts on suitability of different protection circuits may be compiled by utilizing measured arc energy; for quick and direct appraisal of any new protection circuit only few tests will be ncessary; in field of high voltage circuit breaking, important application of meter could be to measure energy associated with opening of circuit breaker.

UR - http://www.scopus.com/inward/record.url?scp=0014618092&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0014618092&partnerID=8YFLogxK

M3 - Chapter

BT - Unknown Host Publication Title

ER -