Effects of hemodialysis therapy on sit-to-walk characteristics in end stage renal disease patients

Rahul Soangra, Thurmon E. Lockhart, John Lach, Emaad M. Abdel-Rahman

Research output: Contribution to journalArticlepeer-review

22 Scopus citations

Abstract

Patients with end stage renal diseases (ESRD) undergoing hemodialysis (HD) have high morbidity and mortality due to multiple causes; one of which is dramatically higher fall rates than the general population. In spite of the multiple efforts aiming to decrease the high mortality and improve quality of life in ESRD patients, limited success has been achieved. If adequate interventions for fall prevention are to be achieved, the functional and mobility mechanisms consistent with falls in this population must be understood. Human movements such as sit-to-walk (STW) tasks are clinically significant, and analysis of these movements provides a meaningful evaluation of postural and locomotor performance in elderly patients with functional limitations indicative of fall risks. In order to assess the effects of HD therapy on fall risks, 22 sessions of both pre- and post-HD measurements were obtained in six ESRD patients utilizing customized inertial measurement units (IMU). IMU signals were denoised using ensemble empirical mode decomposition and Savistky-Golay filtering methods to detect relevant events for identification of STW phases. The results indicated that patients were slower to get out of the chair (as measured by trunk flexion angular accelerations, time to peak trunk flexion, and overall STW completion time) following the dialysis therapy session. STW is a frequent movement in activities of daily living, and HD therapy may influence the postural and locomotor control of these movements. The analysis of STW movement may assist in not only assessing a patient's physical status, but in identifying HD-related fall risk as well. This preliminary study presents a non-invasive method of kinematic measurement for early detection of increased fall risk in ESRD patients using portable inertial sensors for out-patient monitoring. This can be helpful in understanding the pathogenesis better, and improve awareness in health care providers in targeting interventions to identify individuals at risk for fall.

Original languageEnglish (US)
Pages (from-to)795-805
Number of pages11
JournalAnnals of Biomedical Engineering
Volume41
Issue number4
DOIs
StatePublished - Apr 2013
Externally publishedYes

Keywords

  • Fall risk
  • Gait and posture
  • Gait initiation
  • Locomotion
  • Timed Get Up & Go

ASJC Scopus subject areas

  • Biomedical Engineering

Fingerprint

Dive into the research topics of 'Effects of hemodialysis therapy on sit-to-walk characteristics in end stage renal disease patients'. Together they form a unique fingerprint.

Cite this