Abstract

A novel method was developed for the direct detection of amino acids in biological fluids by extractive electrospray ionization (EESI) tandem mass spectrometry (MS) with minimal sample pretreatment. Based on our previous research, a novel EESI ion source was constructed to improve analytical performance and operation safety. The EESI-MS conditions were optimized using representative amino acid standards. The methanol-water reagent solvent (1:1, v/v) was electrosprayed at 5 μL min-1 at a high voltage (+4 kV, positive ion detection mode). The temperature of the heated capillary was optimized to be 150 °C. Collision induced dissociation (CID) experiments were performed by applying 17%-25% of the collision energy to the precursor ions isolated with a window width of 1.5 mass/charge (m/z) units. The limit of detection (LOD) for these amino acids was in the range of 0.14-26.2 μg L -1, and the linear dynamic range was larger than two orders of magnitude. The average time for a single amino acid analysis using a typical human urine sample was less than 0.5 min. The recovery rates for different concentrations of amino acids ranged from 82.6% to 105.6%, and the relative standard deviations (RSD) ranged from 2.2% to 11.4%. The results showed that EESI-MS is a powerful tool for the rapid, sensitive, and quantitative detection of amino acids in complex biological samples.

Original languageEnglish (US)
Pages (from-to)523-528
Number of pages6
JournalFenxi Huaxue/ Chinese Journal of Analytical Chemistry
Volume41
Issue number4
DOIs
StatePublished - Jan 1 2013
Externally publishedYes

Fingerprint

Electrospray ionization
Mass spectrometry
Amino Acids
Ion sources
Methanol
Positive ions
Ions
Recovery
Fluids
Water
Electric potential

Keywords

  • Ambient mass spectrometry
  • Amino acids
  • Extractive electrospray ionization
  • Urine

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Direct detection of amino acids using extractive electrospray ionization tandem mass spectrometry. / Xu, Ning; Zhu, Zhi Qiang; Yang, Shui Ping; Wang, Jiang; Gu, Haiwei; Zhou, Zhen; Chen, Huan Wen.

In: Fenxi Huaxue/ Chinese Journal of Analytical Chemistry, Vol. 41, No. 4, 01.01.2013, p. 523-528.

Research output: Contribution to journalArticle

Xu, Ning ; Zhu, Zhi Qiang ; Yang, Shui Ping ; Wang, Jiang ; Gu, Haiwei ; Zhou, Zhen ; Chen, Huan Wen. / Direct detection of amino acids using extractive electrospray ionization tandem mass spectrometry. In: Fenxi Huaxue/ Chinese Journal of Analytical Chemistry. 2013 ; Vol. 41, No. 4. pp. 523-528.
@article{bbc01ab1f8a5499db167bfdb68b169c3,
title = "Direct detection of amino acids using extractive electrospray ionization tandem mass spectrometry",
abstract = "A novel method was developed for the direct detection of amino acids in biological fluids by extractive electrospray ionization (EESI) tandem mass spectrometry (MS) with minimal sample pretreatment. Based on our previous research, a novel EESI ion source was constructed to improve analytical performance and operation safety. The EESI-MS conditions were optimized using representative amino acid standards. The methanol-water reagent solvent (1:1, v/v) was electrosprayed at 5 μL min-1 at a high voltage (+4 kV, positive ion detection mode). The temperature of the heated capillary was optimized to be 150 °C. Collision induced dissociation (CID) experiments were performed by applying 17{\%}-25{\%} of the collision energy to the precursor ions isolated with a window width of 1.5 mass/charge (m/z) units. The limit of detection (LOD) for these amino acids was in the range of 0.14-26.2 μg L -1, and the linear dynamic range was larger than two orders of magnitude. The average time for a single amino acid analysis using a typical human urine sample was less than 0.5 min. The recovery rates for different concentrations of amino acids ranged from 82.6{\%} to 105.6{\%}, and the relative standard deviations (RSD) ranged from 2.2{\%} to 11.4{\%}. The results showed that EESI-MS is a powerful tool for the rapid, sensitive, and quantitative detection of amino acids in complex biological samples.",
keywords = "Ambient mass spectrometry, Amino acids, Extractive electrospray ionization, Urine",
author = "Ning Xu and Zhu, {Zhi Qiang} and Yang, {Shui Ping} and Jiang Wang and Haiwei Gu and Zhen Zhou and Chen, {Huan Wen}",
year = "2013",
month = "1",
day = "1",
doi = "10.1016/S1872-2040(13)60643-X",
language = "English (US)",
volume = "41",
pages = "523--528",
journal = "Chinese Journal of Analytical Chemistry",
issn = "1872-2040",
publisher = "Elsevier BV",
number = "4",

}

TY - JOUR

T1 - Direct detection of amino acids using extractive electrospray ionization tandem mass spectrometry

AU - Xu, Ning

AU - Zhu, Zhi Qiang

AU - Yang, Shui Ping

AU - Wang, Jiang

AU - Gu, Haiwei

AU - Zhou, Zhen

AU - Chen, Huan Wen

PY - 2013/1/1

Y1 - 2013/1/1

N2 - A novel method was developed for the direct detection of amino acids in biological fluids by extractive electrospray ionization (EESI) tandem mass spectrometry (MS) with minimal sample pretreatment. Based on our previous research, a novel EESI ion source was constructed to improve analytical performance and operation safety. The EESI-MS conditions were optimized using representative amino acid standards. The methanol-water reagent solvent (1:1, v/v) was electrosprayed at 5 μL min-1 at a high voltage (+4 kV, positive ion detection mode). The temperature of the heated capillary was optimized to be 150 °C. Collision induced dissociation (CID) experiments were performed by applying 17%-25% of the collision energy to the precursor ions isolated with a window width of 1.5 mass/charge (m/z) units. The limit of detection (LOD) for these amino acids was in the range of 0.14-26.2 μg L -1, and the linear dynamic range was larger than two orders of magnitude. The average time for a single amino acid analysis using a typical human urine sample was less than 0.5 min. The recovery rates for different concentrations of amino acids ranged from 82.6% to 105.6%, and the relative standard deviations (RSD) ranged from 2.2% to 11.4%. The results showed that EESI-MS is a powerful tool for the rapid, sensitive, and quantitative detection of amino acids in complex biological samples.

AB - A novel method was developed for the direct detection of amino acids in biological fluids by extractive electrospray ionization (EESI) tandem mass spectrometry (MS) with minimal sample pretreatment. Based on our previous research, a novel EESI ion source was constructed to improve analytical performance and operation safety. The EESI-MS conditions were optimized using representative amino acid standards. The methanol-water reagent solvent (1:1, v/v) was electrosprayed at 5 μL min-1 at a high voltage (+4 kV, positive ion detection mode). The temperature of the heated capillary was optimized to be 150 °C. Collision induced dissociation (CID) experiments were performed by applying 17%-25% of the collision energy to the precursor ions isolated with a window width of 1.5 mass/charge (m/z) units. The limit of detection (LOD) for these amino acids was in the range of 0.14-26.2 μg L -1, and the linear dynamic range was larger than two orders of magnitude. The average time for a single amino acid analysis using a typical human urine sample was less than 0.5 min. The recovery rates for different concentrations of amino acids ranged from 82.6% to 105.6%, and the relative standard deviations (RSD) ranged from 2.2% to 11.4%. The results showed that EESI-MS is a powerful tool for the rapid, sensitive, and quantitative detection of amino acids in complex biological samples.

KW - Ambient mass spectrometry

KW - Amino acids

KW - Extractive electrospray ionization

KW - Urine

UR - http://www.scopus.com/inward/record.url?scp=84877293580&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84877293580&partnerID=8YFLogxK

U2 - 10.1016/S1872-2040(13)60643-X

DO - 10.1016/S1872-2040(13)60643-X

M3 - Article

AN - SCOPUS:84877293580

VL - 41

SP - 523

EP - 528

JO - Chinese Journal of Analytical Chemistry

JF - Chinese Journal of Analytical Chemistry

SN - 1872-2040

IS - 4

ER -