Complex Field Mapping of Large Direct Detector Focal Plane Arrays

Kristina K. Davis, Stephen J.C. Yates, Willem Jellema, Christopher Groppi, Jochem J.A. Baselmans, Kotaro Kohno, Andrey M. Baryshev

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Complex field mapping is a powerful tool to characterize the optical performance of astronomical instruments, and has become the standard for characterizing heterodyne array cameras. Recently, an adaptation of the heterodyne beam mapping technique was demonstrated on a single pixel of a direct detector instrument. We present a novel measurement apparatus and data acquisition techniques to efficiently reconstruct the complex field pattern of individual pixels across a direct detector focal plane array. These techniques are scalable to high pixel counts as the technology maturation and scientific requirements push to larger arrays. For this demonstration, we used an engineering model of the low-frequency band of the APEX microwave kinetic inductance detector camera with a center frequency of ν = 350 GHz. Amplitude and phase radiation patterns were measured from all 880 pixels of the test array in two orthogonal polarizations. We also discuss an updated postprocessing pipeline using the complex field data to characterize the optical performance of the array. Using the measured complex field pattern, we extract the co- and cross-polarization patterns and Gaussian beam parameters, and propagate the beam from the measurement plane to additional planes of interest across all pixels in the test array. Complex field measurements of direct detectors allow more precise characterization of beam parameters when compared to thermal measurements, particularly for individualized fitting in postprocessing not reliant on the accuracy of the probe system alignment. These techniques enable high-precision characterization of individualized beam parameters as well as the overall optical system to very large format arrays with modest computational processing power. These results demonstrate the diagnostic power of the presented measurement and analysis techniques.

Original languageEnglish (US)
Article number8550802
Pages (from-to)67-77
Number of pages11
JournalIEEE Transactions on Terahertz Science and Technology
Volume9
Issue number1
DOIs
StatePublished - Jan 1 2019

Fingerprint

Focal plane arrays
focal plane devices
Pixels
Detectors
pixels
detectors
Cameras
Polarization
cameras
Gaussian beams
Optical systems
Inductance
cross polarization
Frequency bands
Data acquisition
inductance
Demonstrations
Pipelines
data acquisition
format

Keywords

  • Complex field mapping
  • Gaussian beam analysis
  • kinetic inductance detector
  • near-to-far-field transformation
  • optical characterization

ASJC Scopus subject areas

  • Radiation
  • Electrical and Electronic Engineering

Cite this

Davis, K. K., Yates, S. J. C., Jellema, W., Groppi, C., Baselmans, J. J. A., Kohno, K., & Baryshev, A. M. (2019). Complex Field Mapping of Large Direct Detector Focal Plane Arrays. IEEE Transactions on Terahertz Science and Technology, 9(1), 67-77. [8550802]. https://doi.org/10.1109/TTHZ.2018.2883820

Complex Field Mapping of Large Direct Detector Focal Plane Arrays. / Davis, Kristina K.; Yates, Stephen J.C.; Jellema, Willem; Groppi, Christopher; Baselmans, Jochem J.A.; Kohno, Kotaro; Baryshev, Andrey M.

In: IEEE Transactions on Terahertz Science and Technology, Vol. 9, No. 1, 8550802, 01.01.2019, p. 67-77.

Research output: Contribution to journalArticle

Davis, KK, Yates, SJC, Jellema, W, Groppi, C, Baselmans, JJA, Kohno, K & Baryshev, AM 2019, 'Complex Field Mapping of Large Direct Detector Focal Plane Arrays', IEEE Transactions on Terahertz Science and Technology, vol. 9, no. 1, 8550802, pp. 67-77. https://doi.org/10.1109/TTHZ.2018.2883820
Davis, Kristina K. ; Yates, Stephen J.C. ; Jellema, Willem ; Groppi, Christopher ; Baselmans, Jochem J.A. ; Kohno, Kotaro ; Baryshev, Andrey M. / Complex Field Mapping of Large Direct Detector Focal Plane Arrays. In: IEEE Transactions on Terahertz Science and Technology. 2019 ; Vol. 9, No. 1. pp. 67-77.
@article{ba2b75d0ab3940509437b476e77121ef,
title = "Complex Field Mapping of Large Direct Detector Focal Plane Arrays",
abstract = "Complex field mapping is a powerful tool to characterize the optical performance of astronomical instruments, and has become the standard for characterizing heterodyne array cameras. Recently, an adaptation of the heterodyne beam mapping technique was demonstrated on a single pixel of a direct detector instrument. We present a novel measurement apparatus and data acquisition techniques to efficiently reconstruct the complex field pattern of individual pixels across a direct detector focal plane array. These techniques are scalable to high pixel counts as the technology maturation and scientific requirements push to larger arrays. For this demonstration, we used an engineering model of the low-frequency band of the APEX microwave kinetic inductance detector camera with a center frequency of ν = 350 GHz. Amplitude and phase radiation patterns were measured from all 880 pixels of the test array in two orthogonal polarizations. We also discuss an updated postprocessing pipeline using the complex field data to characterize the optical performance of the array. Using the measured complex field pattern, we extract the co- and cross-polarization patterns and Gaussian beam parameters, and propagate the beam from the measurement plane to additional planes of interest across all pixels in the test array. Complex field measurements of direct detectors allow more precise characterization of beam parameters when compared to thermal measurements, particularly for individualized fitting in postprocessing not reliant on the accuracy of the probe system alignment. These techniques enable high-precision characterization of individualized beam parameters as well as the overall optical system to very large format arrays with modest computational processing power. These results demonstrate the diagnostic power of the presented measurement and analysis techniques.",
keywords = "Complex field mapping, Gaussian beam analysis, kinetic inductance detector, near-to-far-field transformation, optical characterization",
author = "Davis, {Kristina K.} and Yates, {Stephen J.C.} and Willem Jellema and Christopher Groppi and Baselmans, {Jochem J.A.} and Kotaro Kohno and Baryshev, {Andrey M.}",
year = "2019",
month = "1",
day = "1",
doi = "10.1109/TTHZ.2018.2883820",
language = "English (US)",
volume = "9",
pages = "67--77",
journal = "IEEE Transactions on Terahertz Science and Technology",
issn = "2156-342X",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "1",

}

TY - JOUR

T1 - Complex Field Mapping of Large Direct Detector Focal Plane Arrays

AU - Davis, Kristina K.

AU - Yates, Stephen J.C.

AU - Jellema, Willem

AU - Groppi, Christopher

AU - Baselmans, Jochem J.A.

AU - Kohno, Kotaro

AU - Baryshev, Andrey M.

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Complex field mapping is a powerful tool to characterize the optical performance of astronomical instruments, and has become the standard for characterizing heterodyne array cameras. Recently, an adaptation of the heterodyne beam mapping technique was demonstrated on a single pixel of a direct detector instrument. We present a novel measurement apparatus and data acquisition techniques to efficiently reconstruct the complex field pattern of individual pixels across a direct detector focal plane array. These techniques are scalable to high pixel counts as the technology maturation and scientific requirements push to larger arrays. For this demonstration, we used an engineering model of the low-frequency band of the APEX microwave kinetic inductance detector camera with a center frequency of ν = 350 GHz. Amplitude and phase radiation patterns were measured from all 880 pixels of the test array in two orthogonal polarizations. We also discuss an updated postprocessing pipeline using the complex field data to characterize the optical performance of the array. Using the measured complex field pattern, we extract the co- and cross-polarization patterns and Gaussian beam parameters, and propagate the beam from the measurement plane to additional planes of interest across all pixels in the test array. Complex field measurements of direct detectors allow more precise characterization of beam parameters when compared to thermal measurements, particularly for individualized fitting in postprocessing not reliant on the accuracy of the probe system alignment. These techniques enable high-precision characterization of individualized beam parameters as well as the overall optical system to very large format arrays with modest computational processing power. These results demonstrate the diagnostic power of the presented measurement and analysis techniques.

AB - Complex field mapping is a powerful tool to characterize the optical performance of astronomical instruments, and has become the standard for characterizing heterodyne array cameras. Recently, an adaptation of the heterodyne beam mapping technique was demonstrated on a single pixel of a direct detector instrument. We present a novel measurement apparatus and data acquisition techniques to efficiently reconstruct the complex field pattern of individual pixels across a direct detector focal plane array. These techniques are scalable to high pixel counts as the technology maturation and scientific requirements push to larger arrays. For this demonstration, we used an engineering model of the low-frequency band of the APEX microwave kinetic inductance detector camera with a center frequency of ν = 350 GHz. Amplitude and phase radiation patterns were measured from all 880 pixels of the test array in two orthogonal polarizations. We also discuss an updated postprocessing pipeline using the complex field data to characterize the optical performance of the array. Using the measured complex field pattern, we extract the co- and cross-polarization patterns and Gaussian beam parameters, and propagate the beam from the measurement plane to additional planes of interest across all pixels in the test array. Complex field measurements of direct detectors allow more precise characterization of beam parameters when compared to thermal measurements, particularly for individualized fitting in postprocessing not reliant on the accuracy of the probe system alignment. These techniques enable high-precision characterization of individualized beam parameters as well as the overall optical system to very large format arrays with modest computational processing power. These results demonstrate the diagnostic power of the presented measurement and analysis techniques.

KW - Complex field mapping

KW - Gaussian beam analysis

KW - kinetic inductance detector

KW - near-to-far-field transformation

KW - optical characterization

UR - http://www.scopus.com/inward/record.url?scp=85057876486&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85057876486&partnerID=8YFLogxK

U2 - 10.1109/TTHZ.2018.2883820

DO - 10.1109/TTHZ.2018.2883820

M3 - Article

AN - SCOPUS:85057876486

VL - 9

SP - 67

EP - 77

JO - IEEE Transactions on Terahertz Science and Technology

JF - IEEE Transactions on Terahertz Science and Technology

SN - 2156-342X

IS - 1

M1 - 8550802

ER -