Comparison of the effects of embolic coils and a low porosity stent on cerebral aneurysm fluid dynamics

Haithem Babiker, Breigh Roszelle, L. Fernando Gonzalez, Felipe Albuquerque, Daniel Collins, Arius Elvikis, David Frakes

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Original languageEnglish (US)
Title of host publicationASME 2012 Summer Bioengineering Conference, SBC 2012
Pages609-610
Number of pages2
DOIs
StatePublished - 2012
EventASME 2012 Summer Bioengineering Conference, SBC 2012 - Fajardo, Puerto Rico
Duration: Jun 20 2012Jun 23 2012

Other

OtherASME 2012 Summer Bioengineering Conference, SBC 2012
CountryPuerto Rico
CityFajardo
Period6/20/126/23/12

Fingerprint

Stents
Fluid dynamics
Porosity

ASJC Scopus subject areas

  • Bioengineering

Cite this

Babiker, H., Roszelle, B., Gonzalez, L. F., Albuquerque, F., Collins, D., Elvikis, A., & Frakes, D. (2012). Comparison of the effects of embolic coils and a low porosity stent on cerebral aneurysm fluid dynamics. In ASME 2012 Summer Bioengineering Conference, SBC 2012 (pp. 609-610) https://doi.org/10.1115/SBC2012-80705

Comparison of the effects of embolic coils and a low porosity stent on cerebral aneurysm fluid dynamics. / Babiker, Haithem; Roszelle, Breigh; Gonzalez, L. Fernando; Albuquerque, Felipe; Collins, Daniel; Elvikis, Arius; Frakes, David.

ASME 2012 Summer Bioengineering Conference, SBC 2012. 2012. p. 609-610.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Babiker, H, Roszelle, B, Gonzalez, LF, Albuquerque, F, Collins, D, Elvikis, A & Frakes, D 2012, Comparison of the effects of embolic coils and a low porosity stent on cerebral aneurysm fluid dynamics. in ASME 2012 Summer Bioengineering Conference, SBC 2012. pp. 609-610, ASME 2012 Summer Bioengineering Conference, SBC 2012, Fajardo, Puerto Rico, 6/20/12. https://doi.org/10.1115/SBC2012-80705
Babiker H, Roszelle B, Gonzalez LF, Albuquerque F, Collins D, Elvikis A et al. Comparison of the effects of embolic coils and a low porosity stent on cerebral aneurysm fluid dynamics. In ASME 2012 Summer Bioengineering Conference, SBC 2012. 2012. p. 609-610 https://doi.org/10.1115/SBC2012-80705
Babiker, Haithem ; Roszelle, Breigh ; Gonzalez, L. Fernando ; Albuquerque, Felipe ; Collins, Daniel ; Elvikis, Arius ; Frakes, David. / Comparison of the effects of embolic coils and a low porosity stent on cerebral aneurysm fluid dynamics. ASME 2012 Summer Bioengineering Conference, SBC 2012. 2012. pp. 609-610
@inproceedings{f78b232176534cfbbae480083f1fc006,
title = "Comparison of the effects of embolic coils and a low porosity stent on cerebral aneurysm fluid dynamics",
author = "Haithem Babiker and Breigh Roszelle and Gonzalez, {L. Fernando} and Felipe Albuquerque and Daniel Collins and Arius Elvikis and David Frakes",
year = "2012",
doi = "10.1115/SBC2012-80705",
language = "English (US)",
isbn = "9780791844809",
pages = "609--610",
booktitle = "ASME 2012 Summer Bioengineering Conference, SBC 2012",

}

TY - GEN

T1 - Comparison of the effects of embolic coils and a low porosity stent on cerebral aneurysm fluid dynamics

AU - Babiker, Haithem

AU - Roszelle, Breigh

AU - Gonzalez, L. Fernando

AU - Albuquerque, Felipe

AU - Collins, Daniel

AU - Elvikis, Arius

AU - Frakes, David

PY - 2012

Y1 - 2012

UR - http://www.scopus.com/inward/record.url?scp=84882566443&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84882566443&partnerID=8YFLogxK

U2 - 10.1115/SBC2012-80705

DO - 10.1115/SBC2012-80705

M3 - Conference contribution

AN - SCOPUS:84882566443

SN - 9780791844809

SP - 609

EP - 610

BT - ASME 2012 Summer Bioengineering Conference, SBC 2012

ER -