Bioelectric current image reconstruction from magneto-acoustic measurements

M. R. Islam, B. C. Towe

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

An investigation is conducted of the possibility of reconstructing images of current dipoles in a volume conductor from data obtained by the magnetoacoustic technique. A modified form of the algebraic reconstruction technique (ART) is used. Reconstruction results of simulated data show that it is possible to find the location, relative magnitude, and orientation of the dipoles with reasonable accuracy for simple dipole configurations.

Original languageEnglish (US)
Pages (from-to)386-391
Number of pages6
JournalIEEE Transactions on Medical Imaging
Volume7
Issue number4
DOIs
StatePublished - Dec 1988

Fingerprint

Computer-Assisted Image Processing
Image reconstruction
Acoustics

ASJC Scopus subject areas

  • Computational Theory and Mathematics
  • Computer Science Applications
  • Biomedical Engineering
  • Electrical and Electronic Engineering
  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Bioelectric current image reconstruction from magneto-acoustic measurements. / Islam, M. R.; Towe, B. C.

In: IEEE Transactions on Medical Imaging, Vol. 7, No. 4, 12.1988, p. 386-391.

Research output: Contribution to journalArticle

@article{e76005c94b1845ee97fca0de015c2d4c,
title = "Bioelectric current image reconstruction from magneto-acoustic measurements",
abstract = "An investigation is conducted of the possibility of reconstructing images of current dipoles in a volume conductor from data obtained by the magnetoacoustic technique. A modified form of the algebraic reconstruction technique (ART) is used. Reconstruction results of simulated data show that it is possible to find the location, relative magnitude, and orientation of the dipoles with reasonable accuracy for simple dipole configurations.",
author = "Islam, {M. R.} and Towe, {B. C.}",
year = "1988",
month = "12",
doi = "10.1109/42.14523",
language = "English (US)",
volume = "7",
pages = "386--391",
journal = "IEEE Transactions on Medical Imaging",
issn = "0278-0062",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "4",

}

TY - JOUR

T1 - Bioelectric current image reconstruction from magneto-acoustic measurements

AU - Islam, M. R.

AU - Towe, B. C.

PY - 1988/12

Y1 - 1988/12

N2 - An investigation is conducted of the possibility of reconstructing images of current dipoles in a volume conductor from data obtained by the magnetoacoustic technique. A modified form of the algebraic reconstruction technique (ART) is used. Reconstruction results of simulated data show that it is possible to find the location, relative magnitude, and orientation of the dipoles with reasonable accuracy for simple dipole configurations.

AB - An investigation is conducted of the possibility of reconstructing images of current dipoles in a volume conductor from data obtained by the magnetoacoustic technique. A modified form of the algebraic reconstruction technique (ART) is used. Reconstruction results of simulated data show that it is possible to find the location, relative magnitude, and orientation of the dipoles with reasonable accuracy for simple dipole configurations.

UR - http://www.scopus.com/inward/record.url?scp=0024137368&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024137368&partnerID=8YFLogxK

U2 - 10.1109/42.14523

DO - 10.1109/42.14523

M3 - Article

VL - 7

SP - 386

EP - 391

JO - IEEE Transactions on Medical Imaging

JF - IEEE Transactions on Medical Imaging

SN - 0278-0062

IS - 4

ER -