K. C. Holte, D. E. Alexander, D. M. Baker, R. L. Brown, A. M. Bruning, T. C. Cheng, F. M. Couquelet, T. W. Dakin, I. Kimoto, T. Hillesland, D. C. Jolly, G. Karady, B. E. Kingsbury, S. S. Low, S. T. Mak, J. R. Massey, J. H. Moran, O. Nigol, J. Sakich, H. M. Schneider & 2 others M. Sforzini, H. Songster

Research output: Contribution to journalArticle

48 Citations (Scopus)

Abstract

The application and maintenance of outdoor ceramic insulation on overhead transmission systems has been an art learned by experience. This document combines the experiences of electric utilities, manufacturers, and research laboratories into a single comprehensive report on the design and maintenance of transmission insulation in a contaminated environment. It is intended as a practical reference and guideline to be used by all electric utility engineers and operating personnel. The reader will find a short description of contamination flashover, followed by detailed sections on site severity measurement, test procedures, design practices and maintenance practices. The emphasis in this report is on power frequency voltages, but some occasional references to overvoltages and dc are also made.

Original languageEnglish (US)
Pages (from-to)1676-1695
Number of pages20
JournalIEEE Transactions on Power Apparatus and Systems
VolumePAS-98
Issue number5
DOIs
StatePublished - 1979
Externally publishedYes

Fingerprint

Electric utilities
Insulation
Flashover
Research laboratories
Contamination
Personnel
Engineers
Electric potential

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering
  • Engineering(all)

Cite this

Holte, K. C., Alexander, D. E., Baker, D. M., Brown, R. L., Bruning, A. M., Cheng, T. C., ... Songster, H. (1979). Application of insulators in a contaminated environment. IEEE Transactions on Power Apparatus and Systems, PAS-98(5), 1676-1695. https://doi.org/10.1109/TPAS.1979.319486

Application of insulators in a contaminated environment. / Holte, K. C.; Alexander, D. E.; Baker, D. M.; Brown, R. L.; Bruning, A. M.; Cheng, T. C.; Couquelet, F. M.; Dakin, T. W.; Kimoto, I.; Hillesland, T.; Jolly, D. C.; Karady, G.; Kingsbury, B. E.; Low, S. S.; Mak, S. T.; Massey, J. R.; Moran, J. H.; Nigol, O.; Sakich, J.; Schneider, H. M.; Sforzini, M.; Songster, H.

In: IEEE Transactions on Power Apparatus and Systems, Vol. PAS-98, No. 5, 1979, p. 1676-1695.

Research output: Contribution to journalArticle

Holte, KC, Alexander, DE, Baker, DM, Brown, RL, Bruning, AM, Cheng, TC, Couquelet, FM, Dakin, TW, Kimoto, I, Hillesland, T, Jolly, DC, Karady, G, Kingsbury, BE, Low, SS, Mak, ST, Massey, JR, Moran, JH, Nigol, O, Sakich, J, Schneider, HM, Sforzini, M & Songster, H 1979, 'Application of insulators in a contaminated environment', IEEE Transactions on Power Apparatus and Systems, vol. PAS-98, no. 5, pp. 1676-1695. https://doi.org/10.1109/TPAS.1979.319486
Holte KC, Alexander DE, Baker DM, Brown RL, Bruning AM, Cheng TC et al. Application of insulators in a contaminated environment. IEEE Transactions on Power Apparatus and Systems. 1979;PAS-98(5):1676-1695. https://doi.org/10.1109/TPAS.1979.319486
Holte, K. C. ; Alexander, D. E. ; Baker, D. M. ; Brown, R. L. ; Bruning, A. M. ; Cheng, T. C. ; Couquelet, F. M. ; Dakin, T. W. ; Kimoto, I. ; Hillesland, T. ; Jolly, D. C. ; Karady, G. ; Kingsbury, B. E. ; Low, S. S. ; Mak, S. T. ; Massey, J. R. ; Moran, J. H. ; Nigol, O. ; Sakich, J. ; Schneider, H. M. ; Sforzini, M. ; Songster, H. / Application of insulators in a contaminated environment. In: IEEE Transactions on Power Apparatus and Systems. 1979 ; Vol. PAS-98, No. 5. pp. 1676-1695.
@article{7702261532774908a0ecf00e95faa7e8,
title = "Application of insulators in a contaminated environment",
abstract = "The application and maintenance of outdoor ceramic insulation on overhead transmission systems has been an art learned by experience. This document combines the experiences of electric utilities, manufacturers, and research laboratories into a single comprehensive report on the design and maintenance of transmission insulation in a contaminated environment. It is intended as a practical reference and guideline to be used by all electric utility engineers and operating personnel. The reader will find a short description of contamination flashover, followed by detailed sections on site severity measurement, test procedures, design practices and maintenance practices. The emphasis in this report is on power frequency voltages, but some occasional references to overvoltages and dc are also made.",
author = "Holte, {K. C.} and Alexander, {D. E.} and Baker, {D. M.} and Brown, {R. L.} and Bruning, {A. M.} and Cheng, {T. C.} and Couquelet, {F. M.} and Dakin, {T. W.} and I. Kimoto and T. Hillesland and Jolly, {D. C.} and G. Karady and Kingsbury, {B. E.} and Low, {S. S.} and Mak, {S. T.} and Massey, {J. R.} and Moran, {J. H.} and O. Nigol and J. Sakich and Schneider, {H. M.} and M. Sforzini and H. Songster",
year = "1979",
doi = "10.1109/TPAS.1979.319486",
language = "English (US)",
volume = "PAS-98",
pages = "1676--1695",
journal = "IEEE Transactions on Power Apparatus and Systems",
issn = "0018-9510",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "5",

}

TY - JOUR

T1 - Application of insulators in a contaminated environment

AU - Holte, K. C.

AU - Alexander, D. E.

AU - Baker, D. M.

AU - Brown, R. L.

AU - Bruning, A. M.

AU - Cheng, T. C.

AU - Couquelet, F. M.

AU - Dakin, T. W.

AU - Kimoto, I.

AU - Hillesland, T.

AU - Jolly, D. C.

AU - Karady, G.

AU - Kingsbury, B. E.

AU - Low, S. S.

AU - Mak, S. T.

AU - Massey, J. R.

AU - Moran, J. H.

AU - Nigol, O.

AU - Sakich, J.

AU - Schneider, H. M.

AU - Sforzini, M.

AU - Songster, H.

PY - 1979

Y1 - 1979

N2 - The application and maintenance of outdoor ceramic insulation on overhead transmission systems has been an art learned by experience. This document combines the experiences of electric utilities, manufacturers, and research laboratories into a single comprehensive report on the design and maintenance of transmission insulation in a contaminated environment. It is intended as a practical reference and guideline to be used by all electric utility engineers and operating personnel. The reader will find a short description of contamination flashover, followed by detailed sections on site severity measurement, test procedures, design practices and maintenance practices. The emphasis in this report is on power frequency voltages, but some occasional references to overvoltages and dc are also made.

AB - The application and maintenance of outdoor ceramic insulation on overhead transmission systems has been an art learned by experience. This document combines the experiences of electric utilities, manufacturers, and research laboratories into a single comprehensive report on the design and maintenance of transmission insulation in a contaminated environment. It is intended as a practical reference and guideline to be used by all electric utility engineers and operating personnel. The reader will find a short description of contamination flashover, followed by detailed sections on site severity measurement, test procedures, design practices and maintenance practices. The emphasis in this report is on power frequency voltages, but some occasional references to overvoltages and dc are also made.

UR - http://www.scopus.com/inward/record.url?scp=0018517832&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0018517832&partnerID=8YFLogxK

U2 - 10.1109/TPAS.1979.319486

DO - 10.1109/TPAS.1979.319486

M3 - Article

VL - PAS-98

SP - 1676

EP - 1695

JO - IEEE Transactions on Power Apparatus and Systems

JF - IEEE Transactions on Power Apparatus and Systems

SN - 0018-9510

IS - 5

ER -