A Fast LP Approach for Enhanced Utilization of Variable Impedance Based FACTS Devices

Mostafa Sahraei-Ardakani, Kory Hedman

Research output: Contribution to journalArticle

27 Citations (Scopus)

Abstract

Transmission systems are under stress and need to be upgraded. Better utilization of the existing grid provides a fast and cheap alternative to building new transmission. One way to improve the utilization of the transmission network is power flow control via flexible ac transmission system (FACTS) devices. While FACTS devices are used today, the utilization of these devices is limited; traditional dispatch models (e.g., security constrained economic dispatch) assume a fixed, static transmission grid even though it is rather flexible. The primary barrier is the complexity that is added to the power flow problem. The mathematical representation of the DC optimal power flow, with the added modeling of FACTS devices, is a nonlinear program (NLP). This paper presents a method to convert this NLP into a mixed-integer linear program (MILP). The MILP is reformulated as a two-stage linear program, which enforces the same sign for the voltage angle differences for the lines equipped with FACTS. While this approximation does not guarantee optimality, more than 98% of the presented empirical results, based on the IEEE 118-bus and Polish systems, achieved global optimality. In the case of suboptimal solutions, the savings were still significant and the solution time was dramatically reduced.

Original languageEnglish (US)
JournalIEEE Transactions on Power Systems
DOIs
StateAccepted/In press - Jul 9 2015

Fingerprint

Electric power transmission networks
Flow control
Power control
Economics
Electric potential

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Energy Engineering and Power Technology

Cite this

A Fast LP Approach for Enhanced Utilization of Variable Impedance Based FACTS Devices. / Sahraei-Ardakani, Mostafa; Hedman, Kory.

In: IEEE Transactions on Power Systems, 09.07.2015.

Research output: Contribution to journalArticle

@article{dddb663e21a04bde949a47a9029a46e8,
title = "A Fast LP Approach for Enhanced Utilization of Variable Impedance Based FACTS Devices",
abstract = "Transmission systems are under stress and need to be upgraded. Better utilization of the existing grid provides a fast and cheap alternative to building new transmission. One way to improve the utilization of the transmission network is power flow control via flexible ac transmission system (FACTS) devices. While FACTS devices are used today, the utilization of these devices is limited; traditional dispatch models (e.g., security constrained economic dispatch) assume a fixed, static transmission grid even though it is rather flexible. The primary barrier is the complexity that is added to the power flow problem. The mathematical representation of the DC optimal power flow, with the added modeling of FACTS devices, is a nonlinear program (NLP). This paper presents a method to convert this NLP into a mixed-integer linear program (MILP). The MILP is reformulated as a two-stage linear program, which enforces the same sign for the voltage angle differences for the lines equipped with FACTS. While this approximation does not guarantee optimality, more than 98{\%} of the presented empirical results, based on the IEEE 118-bus and Polish systems, achieved global optimality. In the case of suboptimal solutions, the savings were still significant and the solution time was dramatically reduced.",
author = "Mostafa Sahraei-Ardakani and Kory Hedman",
year = "2015",
month = "7",
day = "9",
doi = "10.1109/TPWRS.2015.2447453",
language = "English (US)",
journal = "IEEE Transactions on Power Systems",
issn = "0885-8950",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - JOUR

T1 - A Fast LP Approach for Enhanced Utilization of Variable Impedance Based FACTS Devices

AU - Sahraei-Ardakani, Mostafa

AU - Hedman, Kory

PY - 2015/7/9

Y1 - 2015/7/9

N2 - Transmission systems are under stress and need to be upgraded. Better utilization of the existing grid provides a fast and cheap alternative to building new transmission. One way to improve the utilization of the transmission network is power flow control via flexible ac transmission system (FACTS) devices. While FACTS devices are used today, the utilization of these devices is limited; traditional dispatch models (e.g., security constrained economic dispatch) assume a fixed, static transmission grid even though it is rather flexible. The primary barrier is the complexity that is added to the power flow problem. The mathematical representation of the DC optimal power flow, with the added modeling of FACTS devices, is a nonlinear program (NLP). This paper presents a method to convert this NLP into a mixed-integer linear program (MILP). The MILP is reformulated as a two-stage linear program, which enforces the same sign for the voltage angle differences for the lines equipped with FACTS. While this approximation does not guarantee optimality, more than 98% of the presented empirical results, based on the IEEE 118-bus and Polish systems, achieved global optimality. In the case of suboptimal solutions, the savings were still significant and the solution time was dramatically reduced.

AB - Transmission systems are under stress and need to be upgraded. Better utilization of the existing grid provides a fast and cheap alternative to building new transmission. One way to improve the utilization of the transmission network is power flow control via flexible ac transmission system (FACTS) devices. While FACTS devices are used today, the utilization of these devices is limited; traditional dispatch models (e.g., security constrained economic dispatch) assume a fixed, static transmission grid even though it is rather flexible. The primary barrier is the complexity that is added to the power flow problem. The mathematical representation of the DC optimal power flow, with the added modeling of FACTS devices, is a nonlinear program (NLP). This paper presents a method to convert this NLP into a mixed-integer linear program (MILP). The MILP is reformulated as a two-stage linear program, which enforces the same sign for the voltage angle differences for the lines equipped with FACTS. While this approximation does not guarantee optimality, more than 98% of the presented empirical results, based on the IEEE 118-bus and Polish systems, achieved global optimality. In the case of suboptimal solutions, the savings were still significant and the solution time was dramatically reduced.

UR - http://www.scopus.com/inward/record.url?scp=84937010474&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84937010474&partnerID=8YFLogxK

U2 - 10.1109/TPWRS.2015.2447453

DO - 10.1109/TPWRS.2015.2447453

M3 - Article

AN - SCOPUS:84937010474

JO - IEEE Transactions on Power Systems

JF - IEEE Transactions on Power Systems

SN - 0885-8950

ER -