A control strategy for improved efficiency in direct-coupled photovoltaic systems through load management

Joseph A. Azzolini, Meng Tao

Research output: Contribution to journalArticle

Abstract

Nearly all photovoltaic (PV) systems involve power management and/or conversion devices. Each of these devices introduces a power loss and has an associated monetary cost. In this paper, a direct-coupled load-managing PV system is proposed that promises both a lower cost and a higher efficiency than conventional systems. Against the prevailing wisdom that the PV power must be managed, the proposed system varies the power demand of the loads by controlling the number of loads connected to the PV array to extract the maximum available power throughout a day without a conventional maximum power point tracker. This system can also regulate its operating voltage to less than ±3% of its target voltage without a DC/DC converter. The proposed control strategy can be applied to many direct-coupled PV systems for improved efficiency. A simulation program was developed for the load-managing system that can simulate its performance with a PV array of any size and any number of loads. The theoretical system efficiency was found to increase with the number of loads being managed and reaches above 99% for a direct-coupled system with just eight ohmic loads. Experimentally, a prototype system with equal and unequal ohmic loads was demonstrated in an outdoor environment that responds to changes in solar irradiance. The control strategy also allows direct-coupled PV systems to be backed up by a secondary power source, e.g. the electric grid, to eliminate their intermittency for applications such as electric vehicle charging. The cost of the control electronics for the load-managing system is less than 1% of the commercial-scale PV system cost. Several challenges in implementing and optimizing the proposed system are discussed.

Original languageEnglish (US)
Pages (from-to)926-936
Number of pages11
JournalApplied Energy
Volume231
DOIs
StatePublished - Dec 1 2018

Fingerprint

photovoltaic system
Costs
cost
Electric potential
DC-DC converters
Electric vehicles
electric vehicle
Electronic equipment
irradiance
simulation

Keywords

  • Direct-coupled system
  • Levelized cost of electricity
  • Load management
  • Load matching
  • Maximum power point tracking
  • Photovoltaic system

ASJC Scopus subject areas

  • Building and Construction
  • Energy(all)
  • Mechanical Engineering
  • Management, Monitoring, Policy and Law

Cite this

A control strategy for improved efficiency in direct-coupled photovoltaic systems through load management. / Azzolini, Joseph A.; Tao, Meng.

In: Applied Energy, Vol. 231, 01.12.2018, p. 926-936.

Research output: Contribution to journalArticle

@article{c5fcbc46e0134c948a81437c9617775f,
title = "A control strategy for improved efficiency in direct-coupled photovoltaic systems through load management",
abstract = "Nearly all photovoltaic (PV) systems involve power management and/or conversion devices. Each of these devices introduces a power loss and has an associated monetary cost. In this paper, a direct-coupled load-managing PV system is proposed that promises both a lower cost and a higher efficiency than conventional systems. Against the prevailing wisdom that the PV power must be managed, the proposed system varies the power demand of the loads by controlling the number of loads connected to the PV array to extract the maximum available power throughout a day without a conventional maximum power point tracker. This system can also regulate its operating voltage to less than ±3{\%} of its target voltage without a DC/DC converter. The proposed control strategy can be applied to many direct-coupled PV systems for improved efficiency. A simulation program was developed for the load-managing system that can simulate its performance with a PV array of any size and any number of loads. The theoretical system efficiency was found to increase with the number of loads being managed and reaches above 99{\%} for a direct-coupled system with just eight ohmic loads. Experimentally, a prototype system with equal and unequal ohmic loads was demonstrated in an outdoor environment that responds to changes in solar irradiance. The control strategy also allows direct-coupled PV systems to be backed up by a secondary power source, e.g. the electric grid, to eliminate their intermittency for applications such as electric vehicle charging. The cost of the control electronics for the load-managing system is less than 1{\%} of the commercial-scale PV system cost. Several challenges in implementing and optimizing the proposed system are discussed.",
keywords = "Direct-coupled system, Levelized cost of electricity, Load management, Load matching, Maximum power point tracking, Photovoltaic system",
author = "Azzolini, {Joseph A.} and Meng Tao",
year = "2018",
month = "12",
day = "1",
doi = "10.1016/j.apenergy.2018.09.198",
language = "English (US)",
volume = "231",
pages = "926--936",
journal = "Applied Energy",
issn = "0306-2619",
publisher = "Elsevier BV",

}

TY - JOUR

T1 - A control strategy for improved efficiency in direct-coupled photovoltaic systems through load management

AU - Azzolini, Joseph A.

AU - Tao, Meng

PY - 2018/12/1

Y1 - 2018/12/1

N2 - Nearly all photovoltaic (PV) systems involve power management and/or conversion devices. Each of these devices introduces a power loss and has an associated monetary cost. In this paper, a direct-coupled load-managing PV system is proposed that promises both a lower cost and a higher efficiency than conventional systems. Against the prevailing wisdom that the PV power must be managed, the proposed system varies the power demand of the loads by controlling the number of loads connected to the PV array to extract the maximum available power throughout a day without a conventional maximum power point tracker. This system can also regulate its operating voltage to less than ±3% of its target voltage without a DC/DC converter. The proposed control strategy can be applied to many direct-coupled PV systems for improved efficiency. A simulation program was developed for the load-managing system that can simulate its performance with a PV array of any size and any number of loads. The theoretical system efficiency was found to increase with the number of loads being managed and reaches above 99% for a direct-coupled system with just eight ohmic loads. Experimentally, a prototype system with equal and unequal ohmic loads was demonstrated in an outdoor environment that responds to changes in solar irradiance. The control strategy also allows direct-coupled PV systems to be backed up by a secondary power source, e.g. the electric grid, to eliminate their intermittency for applications such as electric vehicle charging. The cost of the control electronics for the load-managing system is less than 1% of the commercial-scale PV system cost. Several challenges in implementing and optimizing the proposed system are discussed.

AB - Nearly all photovoltaic (PV) systems involve power management and/or conversion devices. Each of these devices introduces a power loss and has an associated monetary cost. In this paper, a direct-coupled load-managing PV system is proposed that promises both a lower cost and a higher efficiency than conventional systems. Against the prevailing wisdom that the PV power must be managed, the proposed system varies the power demand of the loads by controlling the number of loads connected to the PV array to extract the maximum available power throughout a day without a conventional maximum power point tracker. This system can also regulate its operating voltage to less than ±3% of its target voltage without a DC/DC converter. The proposed control strategy can be applied to many direct-coupled PV systems for improved efficiency. A simulation program was developed for the load-managing system that can simulate its performance with a PV array of any size and any number of loads. The theoretical system efficiency was found to increase with the number of loads being managed and reaches above 99% for a direct-coupled system with just eight ohmic loads. Experimentally, a prototype system with equal and unequal ohmic loads was demonstrated in an outdoor environment that responds to changes in solar irradiance. The control strategy also allows direct-coupled PV systems to be backed up by a secondary power source, e.g. the electric grid, to eliminate their intermittency for applications such as electric vehicle charging. The cost of the control electronics for the load-managing system is less than 1% of the commercial-scale PV system cost. Several challenges in implementing and optimizing the proposed system are discussed.

KW - Direct-coupled system

KW - Levelized cost of electricity

KW - Load management

KW - Load matching

KW - Maximum power point tracking

KW - Photovoltaic system

UR - http://www.scopus.com/inward/record.url?scp=85054001521&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85054001521&partnerID=8YFLogxK

U2 - 10.1016/j.apenergy.2018.09.198

DO - 10.1016/j.apenergy.2018.09.198

M3 - Article

AN - SCOPUS:85054001521

VL - 231

SP - 926

EP - 936

JO - Applied Energy

JF - Applied Energy

SN - 0306-2619

ER -